Skip to main content
Clean Hydrogen Partnership

Small release from a LH2 tanker due to road vibration

Event

Event ID
20
Quality
Description

A liquid hydrogen tanker was travelling on a higway, when the vacuum guaranteeing the thermal insulation of the tank started to degrade. The increased heat transfer caused a pressure build-up and the rupture of the burst disc.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
North America
Country
United States
Date
Component involved
PRD (burst disc)
Failure mode
correct activation & venting
Initiating cause
over-pressurisation (thermal insulation degradation)
Root CAUSE analysis

The INITIATING CAUSE was the deterioration of the thermal insulation of the cryogenic tank
The ROOT CAUSE unknown.

Root causes
Unknown
Date entry in HIAD
01/01/2025

Facility

Application
Hydrogen transport and distribution
Sub-application
LH2 tanker
Hydrogen supply chain stage
All components affected

vacuum thermal insulation; burst disc

Process temperature range [C]
cryogenic temperature (below -50°C)
Process pressure range [MPa]
low to medium pressure (below 2 MPa)
Location type
Open
Location
highway or similar
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Currency
US$
Property loss (onsite)
660
Post-event summary

Zalosh (see references) provides the property damage. The low value of 660 US$ suggests that only a imited part of the load went lost after the rupturing of the burst disc.

Lesson Learnt

Lesson Learnt

The safety measures worked as designed.
The release of cold hydrogen gas trough the vent without ignition confirms the general trend for the transport of liquid hydrogen. The small releases on-the-road, caused by overpressure, very rarely ignite.

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Probable IGNITION SOURCE

References

Sources categories
Zalosh
Reference & weblink

Table III of Appendix A of Zalosh and Short
COMPARATIVE ANALYSIS OF HYDROGEN FIRE AND EXPLOSION INCIDENTS
Quarterly Report No. 2 for Period December 1, 1977 - February 28, 1978
https://www.osti.gov/biblio/6566131
(accessed September 2020)

Event incident I-1971080145 of the PHMSA database (Pipeline and Hazardous Materials Safety Administration, 1996),
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages
(accessed September 2024)

The PHMSA report does not contain the details reported by Zalosh.