Event
- Event ID
- 376
- Quality
- Description
A liquid hydrogen tanker was parked at a parking place. The vacuum on the tanker vessel deteriorated causing inner container pressure increase. When the inner container pressure reached the nominal pressure limit, the safety relief valve automatically vented the trailer.
The vessel was allowed to vent, to allow to reduce the internal pressure to a value safe for transport back to home terminal. The tanker was taken out of service and vacuum problem repaired.- Event Initiating system
- Classification of the physical effects
- Unignited Hydrogen Release
- Nature of the consequences
- leak no ignition
- Macro-region
- North America
- Country
- United States
- Date
- Component involved
- PRD (valve)
- Failure mode
- correct activation & venting
- Initiating cause
- over-pressurisation (thermal insulation degradation)
- Root CAUSE analysis
The INITIAL CAUSE was the activation of the pressure relief valve due to increased internal pressure of the cryogenic vessel.
The ROOT CAUSE was the reduction of the thermal isolation capacity of the isolation external shell of the vessel, due to a deterioration of the vacuum.- Root causes
- Date entry in HIAD
- 16/11/2024
Facility
- Application
- Hydrogen transport and distribution
- Sub-application
- LH2 tanker
- Hydrogen supply chain stage
- All components affected
vent valve
- Process temperature range [C]
- cryogenic temperature (below -50°C)
- Process pressure range [MPa]
- low to medium pressure (below 2 MPa)
- Location type
- Open
- Location
- highway or similar
- Operational condition
Emergency & Consequences
- Number of fatalities
- 0
- Number of injured persons
- 0
- Currency
- US$
- Property loss (onsite)
- 384
- Post-event summary
25 kg of hydrogen were released
- Emergency action
The vessel was allowed to vent, to allow to reduce the internal pressure to a value safe for transport back to home terminal.
Lesson Learnt
- Lesson Learnt
The safety measures in place worked as expected. Releasing (‘’venting”) hydrogen to reduce internal pressure is a standard procedure when travelling. Usually, drivers are able to monitors vessel pressure by regular inspection and therefore perform a venting before the pressures reach the set value of the pressure relief valve. In this case, probably, the stop at the parking place had been too long to detect early enough the thermal isolation deterioration of the vessel, and avoid the valve activation.
In-depth data
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Released amount (kg)
- 6.6994700984103
- Probable IGNITION SOURCE
References
- Sources categories
- PHMSA
- Reference & weblink
Report I-1993050528 of the US Pipeline and Hazardous Materials Safety Administration PHMSA:
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages&PortalPath=%…