Skip to main content
Clean Hydrogen Partnership

Road incident of a LH2 tanker

Event

Event ID
1008
Quality
Description

A tanker-tractor carrying liquid hydrogen overturned and lost vacuum insulation. The hydrogen boiled and vented, but there was no ignition.
The potential for fire or explosion, however, led to precautions that did cause considerable disruption: the interstate highway where the accident occurred was closed and nearby homes and businesses were evacuated.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
North America
Country
United States
Date
Component involved
cryogenic insulation shell
Failure mode
rupture, no ignition
Initiating cause
impact, rollover, crash
Root CAUSE analysis

INITIATING cause was a traffic accident. In absence of information on drivers and driver behaviours, the ROOT CAUSE can be attributed generically to a human error (wrong manoeuvre)

Root causes
Date entry in HIAD
10/10/2024

Facility

Application
Hydrogen transport and distribution
Sub-application
LH2 tanker
Hydrogen supply chain stage
All components affected

vacuum thermal insulation

Process temperature range [C]
cryogenic temperature (below -50°C)
Process pressure range [MPa]
low to medium pressure (below 2 MPa)
Location type
Open
Location
highway or similar
Operational condition
Pre-event occurrences

The sources do no specify if the tanker was full. It can be nevertheless understood from the statement that the hydrogen boiled off and was release that the tanker was still liquid hydrogen to be delivered to a customer (on their return travel, the LH2 tankers contain normally only could gaseous hydrogen).

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Post-event summary

no consequence, but local evacuation

Emergency action

The interstate highway was closed and nearby homes and businesses were evacuated.

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Released amount (kg)
3800
Release pressure [MPa]
1
Probable IGNITION SOURCE

References

Sources categories
Scientific article
Reference & weblink

Ringland, Safety Issues for Hydrogen Powered Vehicle, SANDIA REPORTSAND94-8226
https://www.osti.gov/servlets/purl/10136126
(accessed October 2025)

Incident I-1987090240 of the US Pipeline and Hazardous Materials Safety Administration PHMSA:
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages&PortalPath=%…
(accessed September 2024)