Skip to main content
Clean Hydrogen Partnership

Road collision involving hydrogen trailer

Event

Event ID
1134
Quality
Description

A vehicle transporting 54 compressed hydrogen cylinders stopped at a railroad crossing and was struck from behind by a tractor trailer that did not slow down. Due to the impact, the cylinders were thrown from the vehicle. Three of them had the cylinder caps destroyed by hitting the road, broke the valves releasing hydrogen. The hydrogen was allowed to vent till emptying the cylinders without any intervention.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
North America
Country
United States
Date
Component involved
valve (generic)
Failure mode
rupture, no ignition
Initiating cause
impact, rollover, crash
Root CAUSE analysis

INITIATING CAUSE was a traffic accident.
In absence of information on driver, the ROOT CAUSE is attributed generically to a human error (wrong manoeuvre).

Root causes
Date entry in HIAD
25/10/2024

Facility

Application
Hydrogen transport and distribution
Sub-application
CGH2 cylinders truck
Hydrogen supply chain stage
All components affected

valve

Process temperature range [C]
ambient temperature (-50°C to +50°C)
Process pressure range [MPa]
medium to high pressure (10 to 50 MPa)
Location type
Open
Location
highway or similar
Operational condition
Description of the facility/unit/process/substances

DESCRIPTION OF THE UNIT
According to PHMSA, each cylinder contained 300 gas-cubic feet of hydrogen. Three cylinders were damaged and released 900 gas-ft3. If these values are correct, it corresponds to ca. 2.1 kg of hydrogen released. The total transported hydrogen, in 54 cylinders, was then ca. 39 kg

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Currency
US$
Property loss (onsite)
45.045
Post-event summary

The driver of the other truck that struck the rear of the Linde truck was killed upon impact.

Emergency action

No attempt to stop the leak was made, because the safest way to deal with was to allow hydrogen to vent and empty the cylinders without

Lesson Learnt

Lesson Learnt

According to the shipping company, this accident was beyond our drivers control. The cylinders were adequately secured for normal transportation, but the impact was very violent Still according to the company, there was not a possibility of not having the cylinders leave the truck. In absence of accurate frequency of failure as function of the impact force, it is impossible to draw an independent and fact-based opinion on the need of a better design.

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Released amount (kg)
2.1
Release temperature [°C]
25
Release pressure [MPa]
16.5
Probable IGNITION SOURCE

References

Sources categories
PHMSA
Reference & weblink

Incident E-2005040157 of the US Pipeline and Hazardous Materials Safety Administration PHMSA:
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages&PortalPath=%…
(accessed September 2024)