Event
- Event ID
- 1054
- Quality
- Description
The vehicle was being driven in traffic at low speed when it was struck from behind by a full-size pickup which forced the fuel-cell vehicle forward into another pickup. No hydrogen was released and no one was injured.
The vehicle was extensively damaged on both front and rear ends and later declared a total loss. A vehicle data analysis indicates that the vehicle and controls operated as designed.- Event Initiating system
- Classification of the physical effects
- No Hydrogen Release
- Nature of the consequences
- Macro-region
- North America
- Country
- United States
- Date
- Component involved
- FCEV
- Failure mode
- damage, no release
- Initiating cause
- impact, rollover, crash
- Root CAUSE analysis
INITIATING cause was a traffic accident. In absence of information on drivers and driver behaviours, the ROOT CAUSE can be attributed generically to a human error (wrong manoeuvre)
- Root causes
- Date entry in HIAD
- 01/07/2024
Facility
- Application
- Road vehicles
- Sub-application
- FCEV-LDV
- Hydrogen supply chain stage
- All components affected
FCEV
- Process temperature range [C]
- ambient temperature (-50°C to +50°C)
- Process pressure range [MPa]
- high pressure (above 50 MPa)
- Location type
- Open
- Location
- highway or similar
- Operational condition
Emergency & Consequences
- Number of fatalities
- 0
- Number of injured persons
- 0
- Post-event summary
The vehicle was extensively damaged on both front and rear ends and later declared a total loss.
In-depth data
- Release type
- no release
- Released amount (kg)
- 0
- Release temperature [°C]
- 25
- Probable IGNITION SOURCE
References
- Sources categories
- News
- Reference & weblink
Hydrogencarsnow news of 19 March 2010
https://www.hydrogencarsnow.com/index.php/hydrogen-cars/gm-hydrogen-car…