Release from a storage at a HRS

Event

Event ID
1161
Quality
Description

A release occurred from a high-pressure hydrogen storage vessel at a hydrogen refuelling stations. Immediately after detection, hydrogen was vented out as a safety measure. There was no injury, fatality or property damage.
For the investigation, the vessel was disassembled, and found that there were significant differences in thread length between the plug and the neck, and that the O-ring and the back-up ring had ruptured. The structural analysis for the neck assembly demonstrated that the metal parts were designed with sufficient strength but the force on the back-up ring lead to plastic deformation and rupture.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
Asia
Country
South Korea
Date
Component involved
flange (bolts)
Failure mode
rupture, no ignition
Initiating cause
loss of tightness (wrong operation)
Root CAUSE analysis

The INITIATING CAUSE was the rupture of an O-ring.
The ROOT CAUSE was probably related to an installation of the end plug of the vessel which damaged the O-ring.

Root causes
Date entry in HIAD
01/02/2025

Facility

Application
Hydrogen refuelling station
Sub-application
CGH2 stationary storage
Hydrogen supply chain stage
All components affected

vessel

Process temperature range [C]
ambient temperature (-50°C to +50°C)
Process pressure range [MPa]
medium to high pressure (10 to 50 MPa)
Location type
Open
Location
unknown
Operational condition
Description of the facility/unit/process/substances

DESCRIPTION OF THE UNIT
The high-pressure hydrogen storage vessel had a volume of 487 l

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Property loss (onsite)
0
Post-event summary

The storage vessels hydrogen content was released.

Emergency action

The vesseel was vented.

Lesson Learnt

Lesson Learnt

The detection and mitigation measure worked as designed.
For the rest, too less is known to draw a lesson learnt.

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Release temperature [°C]
25
Probable IGNITION SOURCE

References

Sources categories
News
Reference & weblink

FCHEA Hydorgen and Fuel cell update September 2022
https://www.hydrogenandfuelcellsafety.info/september-2022#Update1
(accessed January 2025)

Kwang Seok Kim, Introduction of the Release Incident at Hydrogen Refueling Station in South Korea, presented at the CHS 2022 CHS Americas Conference, September 20-22 Ca.
(not publicly available)