Description

A LH2 road transporter experienced a fire on a rear tire. The driver tried unsuccessfully to extinguish the fire out with the on-board fire extinguisher, then he called the 911 and disconnected the tractor from the trailer. The local fire-fighter team arrived, closed the highway and started to extinguish the fire. At this point the rupture disc opened due to high pressure built up insider the LH2 trailer, releasing hydrogen gas into the atmosphere. The hydrogen did not ignite. Approximately 35 kg were released. The emergency lasted two hours.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
North America
Country
United States
Date
Component involved
PRD (burst disc)
Failure mode
correct activation & venting
Initiating cause
conventional component failure (fire-tyres)
Root CAUSE analysis

The INITIAL CAUSE and the ROOT CAUSE were a conventional fire on a truck tyre, which increased the temperature and consequently the pressure of the LH2 tank. The pressure control system of the trailer functioned as expected. Although not described in detail, the fire fighting strategy appears having been successful, because the emergency lasted only two hours.

Root causes
Date entry in HIAD
19/09/2024

Facility

Application
Hydrogen transport and distribution
Sub-application
LH2 tanker
Hydrogen supply chain stage
All components affected

burst disc

Process temperature range [C]
cryogenic temperature (below -50°C)
Process pressure range [MPa]
low to medium pressure (below 2 MPa)
Location type
Open
Location
highway or similar
Operational condition
Pre-event occurrences

A tyre fire had started on a rear wheel.

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Currency
US$
Property loss (onsite)
101.500
Post-event summary

Approximately 35 kg were released.

Emergency action

The interstate highway was closed for two hours following the accident. The fire fighting had only to fight the conventional tyre fire. It is unknown how the trailer/tractor restarted the travel. It is probably that it was left to vent completely. From the amount of hydrogen released declared, it could be also deduced that the trailer was almost empty.

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Released amount (kg)
453.592
Probable IGNITION SOURCE

References

Sources categories
PHMSA
Reference & weblink