Event
- Event ID
- 424
- Quality
- Description
A liquid hydrogen tanker was returning empty to its home terminal. When the drivers noted that the inner vessel was building pressure. The drivers advised their supervisor and were advised to find a safe location and to safely vent -off the pressure. The pressure was successfully reduced and the tank stabilised. The trailer could resume the travel.
The inspection found that the annular space vacuum had degenerated to 1000 microns, allowing an increased heat transfer which caused the pressure rise. A vacuum integrity check was completed and the vacuum restored before the next loading of the trailer.- Event Initiating system
- Classification of the physical effects
- Unignited Hydrogen Release
- Nature of the consequences
- leak no ignition
- Macro-region
- North America
- Country
- United States
- Date
- Component involved
- LH2 tank (road tanker)
- Failure mode
- manual venting
- Initiating cause
- over-pressurisation (thermal insulation degradation)
- Root CAUSE analysis
The INITIAL was an increase of the pressure inside the LH2 trailer.
The ROOT CAUSE was a reduction of the thermal isolation capacity of the tank external shell.- Root causes
- Date entry in HIAD
- 01/01/2017
Facility
- Application
- Hydrogen transport and distribution
- Sub-application
- LH2 tanker
- Hydrogen supply chain stage
- All components affected
vacuum thermal insulation
- Process temperature range [C]
- cryogenic temperature (below -50°C)
- Process pressure range [MPa]
- low to medium pressure (below 2 MPa)
- Location type
- Open
- Location
- highway or similar
- Operational condition
- Pre-event occurrences
The LH2 trailer had a capacity of 3500 kg, but it was almost empty, containing only gaseous hydrogen
Emergency & Consequences
- Number of fatalities
- 0
- Number of injured persons
- 0
- Currency
- US$
- Property loss (onsite)
- 900
- Post-event summary
Only 1.0 kg went lost during the manual ' stabilisation' venting.
- Emergency action
The increase in pressure was handled by performing a manual venting which brought back the pressure to a value lower than the nominal one.
Lesson Learnt
- Lesson Learnt
The safe systems and procedures worked as expected. The increase in pressure was due to a decrease of the thermal isolation capacity of the tank external shell.
For these cases, in this type of LH2 trailer-tractor the drivers could continuously monitor the pressure from inside the cabin, and notified the head quarter, receiving instructions. They were trained in performing a procedure called in jargon a ‘ stabilisation’ of the tank pressure, consisting in a manual venting aiming at reducing the pressure well below the nominal value.
In-depth data
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Released amount (kg)
- 1
- Probable IGNITION SOURCE
References
- Sources categories
- PHMSA
- Reference & weblink
Incident I-1999010487 of the US Pipeline and Hazardous Materials Safety Administration PHMSA:
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages&PortalPath=%…
(accessed September 2024)