Skip to main content
Clean Hydrogen Partnership

Near miss due to inadequate purge procedure

Event

Event ID
391
Quality
Description

During a welding operation on a LH2 fill line it was discovered that LH2 was still in the tank although it should have been drained. Hence the potential for a major explosion existed.

Event Initiating system
Classification of the physical effects
No Hydrogen Release
Nature of the consequences
Macro-region
North America
Country
United States
Date
-
Component involved
pipe (generic)
Failure mode
damage, no release
Initiating cause
inadequate or no purge
Root CAUSE analysis

A deviation from procedures had occurred when purging was continued without power to the tank sensing probes in the LH2 tank at the after 400th cycle. Because of the undetected presence of LH2 in the tank, when gaseous nitrogen was introduced, it liquefied and blocked the system.

Root causes
Date entry in HIAD
01/11/2025

Facility

Application
Non-road vehicles
Sub-application
Aerospace
Hydrogen supply chain stage
All components affected

LH2 pipe

Process temperature range [C]
cryogenic temperature (below -50°C)
Location type
Unknown
Location
industrial area
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Emergency action

none

In-depth data

Release type
no release
Released amount (kg)
0
Release pressure [MPa]
0.1
Probable IGNITION SOURCE

References

Sources categories
ORDIN
Reference & weblink

Mishap no 50 in
P. L. Ordin, Review of hydrogen accidents and incidents in NASA operations, 1974, NASA TM X-71565
https://ntrs.nasa.gov/citations/19740020344

Hankinson and Lowesmith, Qualitative Risk Assessment of Hydrogen Liquefaction, Storage and Transportation, FCH JU project IDEALHY, Deliverable 3.10 (2013)
confidential
(accessed October 2025)

Lowesmith et al., Safety issues of the liquefaction, storage and transportation of liquid hydrogen: An analysis of incidents and HAZIDS, Int. J. Hydrogen energy (2014) https://doi.org/10.1016/j.ijhydene.2014.08.002