Event
- Event ID
- 1093
- Quality
- Description
This near-miss occurred at a company producing compressed gas bottles according to customers requests. When preparing a gas mixture containing oxygen and nitrogen, by mistake hydrogen was added, instead of nitrogen. The gas lines did not have clear labelling. The mistake was discovered during analysis, when a small gas sample (less than 5 ml) ignited during flashing.
- Event Initiating system
- Classification of the physical effects
- No Hydrogen Release
- Nature of the consequences
- Macro-region
- Europe
- Country
- Germany
- Date
- Component involved
- CGH2 cylinder(s)
- Failure mode
- n.a.
- Initiating cause
- wrong operation
- Root CAUSE analysis
The INITIATING CAUSE was a human error in connecting the wrong pipeline.
A contributing CAUSE was the lack of clear labelling of the pipelines gases.
The root CAUSE could be attributed to management, which did not consider the risk of gas mixing up and did not adopted preventing measures such as different connector for different (incompatible) gases.- Root causes
- Date entry in HIAD
- 01/07/2024
Facility
- Application
- Chemical industry
- Sub-application
- industrial gases production
- Hydrogen supply chain stage
- All components affected
compresed gas mixture bottle
- Process temperature range [C]
- ambient temperature (-50°C to +50°C)
- Location type
- Confined
- Location
- industrial area
- Operational condition
Emergency & Consequences
- Number of fatalities
- 0
- Number of injured persons
- 0
- Property loss (onsite)
- 0
- Post-event summary
The mixed quantities were small: 0.07 kg hydrogen and 0.33 kg oxygen.
- Emergency action
The building was evacuated.
The bottles containing the potentially explosive mixture were blown up by the police.
Lesson Learnt
- Corrective Measures
The following measures were adopted:
(1) Clear marking of each gas pipeline , visible at working height
(2) Clear labelling of the filling valves with the respective gas type-specific colours and labels
(3) Installation of a protective flap as a mechanical locking of the filling valve
(4) Separate and gas type-specific connections
In-depth data
- Release type
- gas mixture
- Involved substances (% vol)
- H2 (0.07 kg),
O2(0.33 kg) - Released amount (kg)
- 0.07
- Release temperature [°C]
- 25
- Probable IGNITION SOURCE
References
- Sources categories
- ZEMA
- Reference & weblink
Event from German database ZEMA
https://www.infosis.uba.de/index.php/de/site/12981/zema/index/3297.html
(accessed December 2023)Event from German database ZEMA - trnslation
https://www.infosis.uba.de/index.php/de/site/12981/zema/index/3297.html
(accessed December 2023)