Event
- Event ID
- 202
- Quality
- Description
Before loading it with liquid hydrogen, the cryogenic tank had been purged with nitrogen for maintenance work.
After the loading, the drivers failed to stabilise the internal pressure of the tank, which was still too warm. A release of 6000 cu ft (approximately 15 kg) of hydrogen was necessary to avoid over-pressure.- Event Initiating system
- Classification of the physical effects
- Unignited Hydrogen Release
- Nature of the consequences
- Macro-region
- North America
- Country
- United States
- Date
- Component involved
- LH2 tank (road tanker)
- Failure mode
- manual venting
- Initiating cause
- over-pressurisation (wrong operation)
- Root CAUSE analysis
The INITIATING CAUSE was the risk of pressurisation which triggered a manual venting of hydrogen to reduce the internal pressure.
The ROOT CAUSE was that the usual procedure for the loading of the tank had been performed, without considering that the tank had been completely emptied of cold hydrogen and was at room temperature. An adaptation of the usual procedure should applied in these cases.
- Root causes
- Date entry in HIAD
- 20/01/2025
Facility
- Application
- Hydrogen transport and distribution
- Sub-application
- LH2 tanker
- Hydrogen supply chain stage
- All components affected
manual vent
- Process temperature range [C]
- cryogenic temperature (below -50°C)
- Process pressure range [MPa]
- low to medium pressure (below 2 MPa)
- Location type
- Open
- Location
- highway or similar
- Operational condition
Emergency & Consequences
- Number of fatalities
- 0
- Number of injured persons
- 0
- Currency
- US$
- Property loss (onsite)
- 0
- Emergency action
manual venting
Lesson Learnt
- Lesson Learnt
Zalosh et al (see references), concluded their analysis of hydrogen transportation accidents till 1978 with the following conclusions:
"Finally, an encouraging aspect of the transportation incident compilation is that 71% of the hydrogen releases did not lead to an ignition. ... The relatively few ignitions may be due to either to lack of ignition sources or to the rapid dispersal of hydrogen into the atmosphere. In any event, the accident data provide further incentive t o transport , transfer and store hydrogen outdoors away from occupied areas."
In-depth data
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Released amount (kg)
- 14.24652
- Probable IGNITION SOURCE
References
- Sources categories
- Zalosh
- Reference & weblink
Extract from Table III of Appendix A of Zalosh and Short
COMPARATIVE ANALYSIS OF HYDROGEN FIRE AND EXPLOSION INCIDENTS
Quarterly Report No. 2 for Period December 1, 1977 - February 28, 1978
https://www.osti.gov/biblio/6566131
(accessed September 2020)Incident I-1975010012 of the US Pipeline and Hazardous Materials Safety Administration PHMSA:
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages&PortalPath=%…
(accessed September 2024)