Skip to main content
Clean Hydrogen Partnership

Liquid spilling from a LH2 tanker

Event

Event ID
73
Quality
Description

While on a highway, the driver of a liquid hydrogen tanker was notified that vapour was coming out of the back of the trailer. The driver pulled into a safe haven to investigate. After opening the rear cabinet doors, the driver noticed the liquid hydrogen was leaking by the fire control and manual valve for the fill and withdrawal valve. The product was slowly dripping down onto the cabinet floor and vaporising.
The driver could see no visible cause for the product passing through the valves as they were tight. There was no other choice than safely venting the product to the atmosphere. The tanker returned to the home terminal for evaluation.
It was found that the fire control valve failed to close completely due to a piece of ice partially blocking the valve seat. Once that the ice was removed, the valve worked properly. The tanker was returned to service.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
North America
Country
United States
Date
Component involved
valve (fill)
Failure mode
leak, no ignition
Initiating cause
ice formation
Root CAUSE analysis

The INITIATING CAUSE of the liquid hydrogen spilling was the block of a valve in partially open position due to ice formation.
The ROOT CAUSE was probably related to the failing to perform properly the procedure at the moment of the filling of the tanker.

Root causes
Date entry in HIAD
31/12/2024

Facility

Application
Hydrogen transport and distribution
Sub-application
LH2 tanker
Hydrogen supply chain stage
All components affected

fill & withdrawal valve,
fire control valve

Process temperature range [C]
cryogenic temperature (below -50°C)
Process pressure range [MPa]
low to medium pressure (below 2 MPa)
Location type
Open
Location
highway or similar
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Currency
US$
Property loss (onsite)
170
Post-event summary

The source report only a partial loss of the hydrogen content.

Emergency action

The driver vented safely the hydrogen to the atmosphere.

In-depth data

Release type
liquid
Involved substances (% vol)
H2 100%
Probable IGNITION SOURCE

References

Sources categories
PHMSA
Reference & weblink

Event incident ID I-1992020141 of the PHMSA database (Pipeline and Hazardous Materials Safety Administration, 1996),
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages
(accessed September 2024)