Skip to main content
Clean Hydrogen Partnership

Leak from a valve of a LH2 tanker

Event

Event ID
75
Quality
Description

The driver of a liquid hydrogen tanker noticed a small vapour plume in his mirror while driving. The driver stopped and found the packing nut had loosened on the vapour recovery valve causing the valve to crack open. The driver closed the valve and tightened the packing nut. The vapour stopped and the driver continued on to complete trip without further incident.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
North America
Country
United States
Date
Component involved
flange (bolts)
Failure mode
rupture, no ignition
Initiating cause
loss of tightness (road vibrations)
Root CAUSE analysis

The INITIATING cause of the hydrogen release was the loosening of valve packing nut.

The ROOT CAUSE was identified by the PHMSA report with over pressurisation. However, the loosening of the packing nut could more plausibly be attributed to road vibrations.

Root causes
Unknown
Date entry in HIAD
31/12/2024

Facility

Application
Hydrogen transport and distribution
Sub-application
LH2 tanker
Hydrogen supply chain stage
All components affected

packing nut, valve

Process temperature range [C]
cryogenic temperature (below -50°C)
Process pressure range [MPa]
low to medium pressure (below 2 MPa)
Location type
Open
Location
highway or similar
Operational condition
Pre-event occurrences

Unknown if the tanker was containing liquid hydrogen or only cold hydrogen vapour.

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Currency
US$
Property loss (onsite)
3
Post-event summary

PHMSA reports a minimal loss of hydrogen of 60 GCF, which probably correspond to 0.2 kg

Emergency action

The driver closed the valve and tightened the packing nut.

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Probable IGNITION SOURCE

References

Sources categories
PHMSA
Reference & weblink

Event incident ID I-1991110674 of the PHMSA database (Pipeline and Hazardous Materials Safety Administration, 1996),
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages
(accessed September 2024)