Skip to main content
Clean Hydrogen Partnership

Leak from a cryogenic tank

Event

Event ID
322
Quality
Description

A large hydrogen gas leak from a dewar resulted when bolts holding fitting the top of the tank was loosened. The fitting contained instruments. On loosening the third bolt, hydrogen gas excaped from the opening around seal. The Viton or neoprene 0-ring was blown out of its groove and was immediately frozen, making it impossible to reseal the fitting cover. The area was evacuated, dewar vented and gasket replaced. The ullage space was not purged with helium gas during the gasket replacement which may have been responsible for small leaks which developed during the transfer.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
North America
Country
United States
Date
-
Component involved
flange (bolts)
Failure mode
erroneous release & ignition
Initiating cause
loss of tightness (wrong operation)
Root CAUSE analysis

The INITIATING CAUSE was a release from a flange sealing.
The fitting which contained the instruments was mounted on a flange, which in turn, was secured to another flange. A set of long bolts and short bolts were used to retain the components. The bolt heads were identical and not labelled, therefore an error was made in loosening the wrong bolts. Leaks after gasket replacement probably due to condensation of moisture on related vent valve components.
The ROOT CAUSE was a human error facilitated by lack of clear guidelines/procedures.

Root causes
Date entry in HIAD
30/10/2025

Facility

Application
Non-road vehicles
Sub-application
Aerospace
Hydrogen supply chain stage
All components affected

cryogenic tank

Process temperature range [C]
cryogenic temperature (below -50°C)
Location type
Unknown
Location
countryside or desert
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0

Lesson Learnt

Lesson Learnt

H2TOOLS proposed improvement based on the need to clearly label bolts according to their function/role
Bolts could be identified by means of colour coding. Obviously, an explanation of the colour coding should be easily available at the working place.

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Release pressure [MPa]
<1.0
Probable IGNITION SOURCE

References

Sources categories
ORDIN
Reference & weblink

Mishap no 32 in
P. L. Ordin, Review of hydrogen accidents and incidents in NASA operations, 1974, NASA TM X-71565
https://ntrs.nasa.gov/citations/19740020344

Hankinson and Lowesmith, Qualitative Risk Assessment of Hydrogen Liquefaction, Storage and Transportation, FCH JU project IDEALHY, Deliverable 3.10 (2013)
confidential
(accessed October 2025)

Lowesmith et al., Safety issues of the liquefaction, storage and transportation of liquid hydrogen: An analysis of incidents and HAZIDS, Int. J. Hydrogen energy (2014) https://doi.org/10.1016/j.ijhydene.2014.08.002

Also H2TOOLS uploded from Ordin
https://h2tools.org/lessons/technician-accidentally-removes-critical-bo…
(accessed December 2025)