Skip to main content
Clean Hydrogen Partnership

Hydrogen release from a CGH2 bottles trailer

Event

Event ID
907
Quality
Description

A pallet containing 9 hydrogen cylinders was damaged during the operation of unloading the cylinders trailer by means of a forklift.
A 2 mm wide crack, caused by the fork, was observed on a flexible.
The fire brigade decided for an emergency and evacuation zone of 200 m.
The intervention of an expert allowed to measure a remaining pressure in the pallet of 100 bar. He tightened a nut and stopped the leak after approximately 3 hours. The amount of hydrogen released was estimated at 30 m3.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
Europe
Country
France
Date
Component involved
piping (generic)
Failure mode
rupture, no ignition
Initiating cause
impact, rollover, crash
Root CAUSE analysis

INITIATING CAUSE was the damage of compressed hydrogen cylinders by a forklift. In absence of information on driver, the ROOT CAUSE is attributed generically to a human error (wrong manoeuvre).
The responsibility of the operative management in guaranteeing safety measure able to prevent or mitigate such an event is not evident but cannot be excluded either.

Root causes
Date entry in HIAD
01/01/2018

Facility

Application
Hydrogen transport and distribution
Sub-application
CGH2 cylinders truck
Hydrogen supply chain stage
All components affected

cylinders

Process temperature range [C]
ambient temperature (-50°C to +50°C)
Process pressure range [MPa]
medium to high pressure (10 to 50 MPa)
Location type
Open
Location
highway or similar
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Emergency action

The fire brigade decided for an emergency zone of 200 m. Workers of 20 companies were evacuated.
The traffic on neighbouring roads stopped.

Lesson Learnt

Lesson Learnt

Better operative procedures used for the unloading process of compressed hydrogen bottles were required. The load/unloading process are the two operations most affected by hazards, in particularly the unloading of full bottles at the customer sites, where not always the required infrastructure is available.
In alternative, or addition, a better structural protection of the pressurised components of the pellet would increase the level of safety of those operations.

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Released amount (kg)
3
Release temperature [°C]
25
Release pressure [MPa]
20
Probable IGNITION SOURCE

References

Sources categories
ARIA
Reference & weblink

Event description in French database ARIA
https://www.aria.developpement-durable.gouv.fr/accident/1380/
(accessed September 2020)