Skip to main content
Clean Hydrogen Partnership

fire at the top of a vent stack

Event

Event ID
436
Quality
Description

A fire occurred on top of a vent stack attached to a LH2 vessel. The ignition source was unknown but electrical storms in the vicinity may have been responsible. The flame was extinguished by purging the line with helium.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
Macro-region
North America
Country
United States
Date
-
Component involved
venting system (exit)
Failure mode
ignition of vented H2
Initiating cause
extreme environmental conditions (lightning)
Root CAUSE analysis

Too less details, ROOT CAUSE analysis impossible.

Root causes
Unknown
Date entry in HIAD
01/11/2025

Facility

Application
Non-road vehicles
Sub-application
Aerospace
Hydrogen supply chain stage
All components affected

vent stack

Process temperature range [C]
cryogenic temperature (below -50°C)
Location type
Open
Location
industrial area
Operational condition
UNKNOWN

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Emergency action

The flame was extinguished by purging the line with helium.

In-depth data

Release type
liquid
Involved substances (% vol)
H2 100%
Probable IGNITION SOURCE
Explosion type

References

Sources categories
ORDIN
Reference & weblink

Mishap no 77 in
P. L. Ordin, Review of hydrogen accidents and incidents in NASA operations, 1974, NASA TM X-71565
https://ntrs.nasa.gov/citations/19740020344

Hankinson and Lowesmith, Qualitative Risk Assessment of Hydrogen Liquefaction, Storage and Transportation, FCH JU project IDEALHY, Deliverable 3.10 (2013)
confidential
(accessed October 2025)

Lowesmith et al., Safety issues of the liquefaction, storage and transportation of liquid hydrogen: An analysis of incidents and HAZIDS, Int. J. Hydrogen energy (2014) https://doi.org/10.1016/j.ijhydene.2014.08.002