Event
- Event ID
- 22
- Quality
- Description
The event occurred on a crude oil cracker. A pipe ruptured on the carbon dioxide absorption tower in the carbon monoxide purification process. Hydrogen, carbon monoxide and carbon dioxide were released and ignited.
No injuries occurred.
- Event Initiating system
- Classification of the physical effects
- Unignited Hydrogen Release
- Nature of the consequences
- leak no ignition
- Macro-region
- Asia
- Country
- Japan
- Date
- Component involved
- pipe (generic)
- Failure mode
- internal explosion
- Initiating cause
- run-away reaction
- Root CAUSE analysis
The initiating casue of the rupture was due to water in the feed crude oil, which changed the composition of the gas mixture and induced an excessive reaction and an unusual rise in pressure.
ROOT CAUSE unknown- Root causes
- Unknown
- Date entry in HIAD
- 28/02/2009
Facility
- Application
- Petrochemical industry
- Sub-application
- Hydrocracking process
- Hydrogen supply chain stage
- All components affected
oil cracker
- Process temperature range [C]
- Very high temperature (500°C to 1000°C)
- Process pressure range [MPa]
- medium to high pressure (10 to 50 MPa)
- Location type
- Semiconfined
- Location
- industrial area
- Operational condition
- UNKNOWN
Emergency & Consequences
- Number of fatalities
- 0
- Number of injured persons
- 0
In-depth data
- Release type
- gas mixture
- Involved substances (% vol)
- H2,
CO,
CO2 - Probable IGNITION SOURCE
- Explosion type
References
- Sources categories
- Scientific article
- Reference & weblink
From Bockholts and Koehorst,
Handbuch Störfälle, 1992
https://searchworks.stanford.edu/view/2727450Event nr 12562 of the UK database ICHEME in PDF format
https://www.icheme.org/knowledge/safety-centre/resources/accident-data/
(accessed October 2020)