Fire at a naphtha reformer

Event

Event ID
524
Quality
Description

Carbon steel corrosion resulted in release of hydrogen at 500°C from the hydrogen reformer, resulting in a fire.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
fire
Macro-region
North America
Country
United States
Date
Component involved
pipe (generic)
Failure mode
rupture & ignition
Initiating cause
H2-driven material degradation
Root CAUSE analysis

The INITIATING CAUSE was the degradation of a carbon steel, easily degrading in presence of hydrogen.
The ROOT CAUSE was probably a shortcoming in the choice of materials, due to a lack of knowledge related to steel behaviour in hydrogen atmospheres.

Root causes
Date entry in HIAD
28/01/2026

Facility

Application
Petrochemical industry
Sub-application
naphtha reforming
Hydrogen supply chain stage
Process temperature range [C]
Very high temperature (500°C to 1000°C)
Location type
Open
Location
industrial area
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Currency
US$
Property loss (onsite)
0

In-depth data

Release temperature [°C]
500
Probable IGNITION SOURCE

References

Sources categories
Zalosh
Reference & weblink

Table II - Industrial Incidents of Appendix A of Zalosh and Short
COMPARATIVE ANALYSIS OF HYDROGEN FIRE AND EXPLOSION INCIDENTS
Quarterly Report No. 2 for Period December 1, 1977 - February 28, 1978
https://www.osti.gov/biblio/6566131
(accessed September 2020)