Event
- Event ID
- 1106
- Quality
- Description
A hydrogen leak in the hydrogen compressor unit of a filling station ignited causing the shut down of the whole station.
The loss of containment was due the failure of a tie rod (diameter ~64mm) , which had the structural function holding together all compressor parts. The failure caused an hydrogen leak at high pressure. A large amount of hydrogen was released from the compressor to the compressor container within a short time, ignited followed by a deflagration or explosion inside the container. A part of the tie rod was shot to the side wall of the container. One door of the container was detached and was stopped by the fence in 10 m distance.
Firgefighters were on site within 10 min and got quickly the fire under control .
No injury, considerable material damage, limited to two containers.- Event Initiating system
- Classification of the physical effects
- Hydrogen Release and Ignition
- Nature of the consequences
- Macro-region
- Europe
- Country
- Germany
- Date
- Component involved
- compressor / booster / pump
- Failure mode
- rupture & ignition
- Initiating cause
- manufacturing defect/error
- Root CAUSE analysis
INITIATING CAUSE:
Mechanical failure of a structural component of the hydrogen compressor.ROOT CAUSE :
The metallographic investigation revealed that the tie rod failed by inter-granular brittle fracture, suggesting a wrong thermal treatment of the rod material.- Root causes
- Date entry in HIAD
- 20/07/2024
Facility
- Application
- Hydrogen refuelling station
- Sub-application
- HRS
- Hydrogen supply chain stage
- All components affected
tie rod,
compressor- Process temperature range [C]
- ambient temperature (-50°C to +50°C)
- Process pressure range [MPa]
- high pressure (above 50 MPa)
- Location type
- Open
- Location
- industrial area
- Operational condition
- Pre-event occurrences
The hydrogen refuelling station had been opened a week before the incident.
A CGH2 tube trailer was on site, probably to deliver hydrogen to the HRS>- Description of the facility/unit/process/substances
DESCRIPTION OF THE REFUELLING STATION
The fuelling station delivers LNG and hydrogen. The hydrogen part is newer.
It has two dispensers to provide 350 and 700 bar hydrogen serving private cars, buses, special vehicles to heavy trucks.
Its capacity is 500 kilograms per day, able to refuel 10 to 20 commercial vehicles.
Emergency & Consequences
- Number of fatalities
- 0
- Number of injured persons
- 0
- Post-event summary
Damage unknown. From the pictures provided by the sources, the compressor housing and its contents appears destroyed.
The refuelling station operator plans to resume supplying vehicles with hydrogen in the autumn.
The compressor manufacturer checked the three other systems installed in other hydrogen refuelling stations.- Emergency action
The fire brigade established a safety perimeter, closed the valve feeding the compressor. By using several permanent extinguishers they kept cooled the components and a trailer present on site.
The fire was quickly under control.
https://www.feuerwehr-neusaess.de/einsatzbericht/brand-wasserstoff-tankstelle/
Lesson Learnt
- Lesson Learnt
The safety measures in place worked as intended.
A preliminary conclusion from this and similar events is that the individual technologies belonging to the hydrogen supply chain are still not yet fully mature. Possible causes are (i) the limited field experience gained so far, and (ii) the small amount of components produced, which hinders fully fledged quality insurance.- Corrective Measures
The compressor manufacturer made a recall action of all machines with tie rods of the same batch. It introduced also an ultrasonic testing of all newly produced tie rods.
In-depth data
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Release temperature [°C]
- 25
- Release pressure [MPa]
- 70
- Probable IGNITION SOURCE
- Explosion type
References
- Sources categories
- Investigation report
- Reference & weblink
The investigation report by TÜV Süd is not publicly available. A summary was shared by NOW in a presentation of 8 Octobr 2024
PV-Magazine news of 07 July 2024:
https://www.pv-magazine.de/2024/07/11/beschaedigter-kompressor-verursac…
(accessed July 2024)JRC discussion based on own collection of information
Evenr no.62474 of the French database ARIA
https://www.aria.developpement-durable.gouv.fr/accident/62474/
(accessed May 2026)