Fire at a generator of a power plant

Event

Event ID
521
Quality
Description

A technical failure in the High-Pressure turbine blades caused high vibrations in lubricating oil pipes. Some pipes broke off and the oil leak caught fire from hot surfaces. Also the generator's hydrogen leaked out and exploded.
The fire caused the loss of control air and electrical power of several safety-related components: for instance, two turbo-blowers and main heat exchanges were inoperable The fire also affected a main circulation water pipe expansion joint causing outpouring of sea water which caused the flood of the lower levels of the turbine and reactor buildings

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
Macro-region
Europe
Country
Spain
Date
Component involved
H2 coolant system
Failure mode
rupture & ignition
Initiating cause
conventional component failure (turbine-generator)
Root CAUSE analysis

The explosion was caused by turbine vibrations which led to rupture of a fastener beating of the turbine shaft.

Root causes
Date entry in HIAD
01/01/2017

Facility

Application
Power plant
Sub-application
Nuclear power plant
Hydrogen supply chain stage
All components affected

generator, HP turbine, turbine blades, oil, hydrogen

Process pressure range [MPa]
low to medium pressure (below 2 MPa)
Location type
Confined
Location
industrial area
Operational condition
Pre-event occurrences

A technical failure in the HP turbine blades caused high vibrations in lubricating oil pipes. Some pipes broke off and the oil leak caught fire from hot surfaces.

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Currency
$
Property loss (onsite)
100.000.000
Post-event summary

Fire damaged one of the 2 turbine generators.
The turbine vibrations also led to rupture of a condenser intake pipe, with an ensuing flood that unlashed an estimated total of 4000 cubic meters of water in lower floors of the turbine and reactor buildings.
The extent of the damage is estimated at $ 100 million.

Emergency action

It took 4 hours to bring the fire under control, When the fire was extinguished 2 of the 4 gas circulator systems and 2 of the 4 main heat exchanger systems were knocked out and 2 RHR systems in the reactor basements were disabled by flooding.

Lesson Learnt

Lesson Learnt

Generic lesson learnt from major Nuclear Power Plants accidents can be found in

IAEA, Experience gained from fires in nuclear power plants: , IAEA-TECDOC-1421
Available at https://www-pub.iaea.org/MTCD/publications/PDF/TE_1421_web.pdf

In-depth data

Release type
gas-liquid mixture
Involved substances (% vol)
H2,
oil
Release pressure [MPa]
0.4
Probable IGNITION SOURCE
Explosion type

References

Sources categories
IAEA
Reference & weblink

IAEA, Experience gained from fires in nuclear power plants: Lessons learned, 2004, IAEA-TECDOC-1421
Available at https://www-pub.iaea.org/MTCD/publications/PDF/TE_1421_web.pdf
(accessed July 2024)

WIKIPEDIA page dedicated to the accident https://en.wikipedia.org/wiki/Vandell%C3%B2s_I_nuclear_incident
(accessed October 2025)

WISE International

This event is listed in From T. VIROLAINEN, J. MARTTILA, H. AULAMO, "TURRBINE GENERATORS AT VVER-440 NUCLEAR POWER PLANTS”, in "Upgrading of fire safety in nuclear power plants", IAEA-TECDOC-1014, Proceedings of an International Symposium, Vienna (Austria), 18-21 November 1997
https://www.iaea.org/publications/5310/upgrading-of-fire-safety-in-nucl…
(accessed July 2024)

Full report T. VIROLAINEN, J. MARTTILA, H. AULAMO, "TURRBINE GENERATORS AT VVER-440 NUCLEAR POWER PLANTS”, in "Upgrading of fire safety in nuclear power plants", IAEA-TECDOC-1014, Proceedings of an International Symposium, Vienna (Austria), 18-21 November 1997
https://www.iaea.org/publications/5310/upgrading-of-fire-safety-in-nucl…
(accessed July 2024)