Skip to main content
Clean Hydrogen Partnership

Explosion at a refinery

Event

Event ID
51
Quality
Description

An explosion followed by a fire occurred at a refinery, due to the rupture of a hydrogen line inside a hydrogen heater.
Since the refinery control room noticed something wrong with the equipment’s readings, an employee was sent to check on the hydrogen heater. Sometime its arrival on location, the explosion occurred.
The reason for the release remained unknown.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
Macro-region
North America
Country
United States
Date
Component involved
heat exchanger (pipe)
Failure mode
internal explosion
Initiating cause
unknown
Root causes
Unknown
Date entry in HIAD
28/02/2009

Facility

Application
Petrochemical industry
Sub-application
Unspecified refinery process
Hydrogen supply chain stage
All components affected

unknown

Location type
Unknown
Location
industrial area
Operational condition
UNKNOWN
Description of the facility/unit/process/substances

DESCRIPTION OF THE PROCESSES
The ' hydrogen heater' affectted by the incident was probably the fired heater used to pre-heat the feedstock to a refinery process such as a hydron-cracker or hydro-desuplphurisation unit (see for example HIAD_656).

Emergency & Consequences

Number of fatalities
0
Number of injured persons
1
Post-event summary

One injured worker sustained second and third degree burns to his back and face.
The hydrogen heater suffered heavy structural damage
No off-site impact.

Emergency action

Large water cannons, permanently mounted throughout the sprawling facility, were used to cool the hydrogen heater. Officials also injected nitrogen into the line to purge the remaining hydrogen and allowed it to burn off.

Lesson Learnt

Lesson Learnt

Rupture of hydrogen or process gases tubes in pre-heaters /heat-exchangers / fired heaters is a recurrent event up to recent times. This is not surprising, considering the high temperatures and pressures involved. The most common causes are materials degradations due to manufacturing defects and operative stresses. Ruptures tend to happen during operative transients, which may cause over-heating due to reduction of flows. When the releases occur also in presence of naked flames, as in fired heaters, which use conventional fuels burners, ignition and explosion in the confined of the heater box is ensured. Nevertheless, due to sturdy heater constructions, it rarely happens that damage extends to the outside environment.

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Probable IGNITION SOURCE
Explosion type

References

Sources categories
News
Reference & weblink

KSLA news od 03 March 2004
https://www.ksla.com/story/1684394/explosion-at-shreveport-refinery-inj…
(accessed Decemebr 2023)

HIAD 1.0 reporting template (Original source unavailable).