Explosion in the fuel cells compartment of a hydrogen bus

Event

Event ID
1152
Quality
Description

A fuel cells and hydrogen city bus was refuelling at a hydrogen refilling station. It had just terminated this operation and the engine was restarted, that an explosion occurred at the back of the vehicle, causing serious injuries to three persons. The explosion was located in the fuel cells compartment, and some source report that it occurred 11 seconds after the restart of the bus. The sources report also that there was no fire. However, the very fuzzy video shared by the sources reveals a considerable development of smoke, which let suspect that some kind of flash fire occurred.
One of the source reported that the incident was the occasion for another municipality to investigate the tightness of its fleet of 141 fuel cells buses, finding that approximately 20% of the buses were affected by small leaks, possibly caused by loose bolts connecting on the hydrogen fuel lines. The municipality fixed the mishaps and planned a regular inspection process.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
Macro-region
Asia
Country
South Korea
Date
Component involved
FCEV bus
Failure mode
rupture & ignition
Initiating cause
unknown
Root CAUSE analysis

The most plausible INITIATING CAUSE could be a small leak from some components in the fuel dells compartment during refuelling, which was able to create a explosive mixture and which ignited when the bus was turned on after refuelling.
The investigation by exprts could not identify any cause for the explosion.
From the finding of the later inspection to all the city fuel cell buses, regarding hydrogen small leaks, two ROOT CAUSE could be hypothetical advanced:
(i) One related to the lack of proper inspection, able to detect leaks causing hydrogen concentration in the fuel cell compartment above the safety values avoiding formation of explosive mixtures.
(ii) Another related to a lack of an effective risk assessment before designing the fuel cell compartment of the bus, creating the possibility of formation of explosive mixture there.

Root causes
Unknown
Date entry in HIAD
03/01/2025

Facility

Application
Road vehicles
Sub-application
FCEV-bus
Hydrogen supply chain stage
Process temperature range [C]
ambient temperature (-50°C to +50°C)
Process pressure range [MPa]
medium to high pressure (10 to 50 MPa)
Location type
Open
Location
populated area
Operational condition
Pre-event occurrences

A fault code had appeared in the instrument dashboard. The bus did not showed anything abnormal during the journey. Nevertheless, it had ben decided to travel to the service centre for controls. Before doing this, however, the bus had to refuel. and was scheduled to travel to the service centre.

The bus was in service since two years.

Emergency & Consequences

Number of fatalities
0
Number of injured persons
3
Post-event summary

The explosion seriously injured a gas station employee, who was struck in the face by debris. The driver and a mechanic, who were present at the scene, also suffered facial burns from the blast.

Emergency action

The fire brigade intervened. A thorough check of the whole refuelling station was performed, to check the possibility of an escalation. No presence of hydrogen was detected.
The city suspended all 18 hydrogen buses operating in the region.

Lesson Learnt

Lesson Learnt

(i) The ventilation in closed and semi-closed compartment of a hydrogen vehicle has to be designed to take into account possible hydrogen leak and to avoid formation of explosive mixture. To do so, proper accidental scenarios have to be considered during the risk assessment phase.
(ii) In this case, it is probable that the leak rate in the fuel cell compartment was larger than the one considered in the design accidental scenarios, allowing the formation of an explosive mixture.
(iii) Proper inspection should be able to detect and prevent too high leak rate.

[Note of the event validator: when this this evented was entered in HIAD (January 2025), the investigation was still ongoing and nothing is reported on the causes. The conclusions presented here have to be considered only a speculative exercise].

Corrective Measures

One of the city with a high number of the fuel cells bus of the type involved in this incident, t the let the buses been investigated by a team of experts. They found that they were affected by small leaks, possibly caused by loose bolts on the hydrogen fuel lines connections.
The connections were improved, after which the municipality planned an own regular inspection process, probably on top of the existing maintenance provided by the bus manufacturer.

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Release temperature [°C]
25
Probable IGNITION SOURCE
Explosion type

References

Sources categories
news
Reference & weblink

Hydrogen Insight news of 13 January 2025
https://www.hydrogeninsight.com/transport/one-in-nine-hyundai-hydrogen-…
(Accessed January 2025)

Event nr 64748 of the French database ARIA
https://www.aria.developpement-durable.gouv.fr/accident/64748/
(accessed Decemebr 2025)

Hydrogen Insight news of 27 January 2026
https://www.hydrogeninsight.com/transport/korean-police-fail-to-explain…
(Accessed April 2026)