Event
- Event ID
- 177
- Quality
- Description
In a chlorine electrolysis facility, a mixture of oxygen and hydrogen in one of the electrolyser cells a short-circuit ignited causing a deflagration. The cover of the cell was a thin plastic film which broke as planned. The production was stopped.
According to the investigation, the inlet line of the electrolyte in the cell was blocked, which lead to an increase of the temperature in the cell and to the increase of oxygen production. On top of that, the alarm related to temperature control did not function.
- Event Initiating system
- Classification of the physical effects
- Hydrogen Release and Ignition
- Nature of the consequences
- Macro-region
- Europe
- Country
- France
- Date
- Component involved
- electrolytic cell
- Failure mode
- internal explosion
- Initiating cause
- malfunctioning (electrolyser, cross-over)
- Root CAUSE analysis
The INITIATING cause was a malfunction in the cell of a chlorine electrolyser.
Contributing cause was the malfunctioning of the alarm system related to the temperature monitoring of the process.The root cause was probably an underestimation of this hazard in the safety design of the process. Nevertheless, a correct mitigating measure (weak enclosure to reduce the risk of a e deflagration) operated as designed and limited damage,
- Root causes
- Date entry in HIAD
- 28/02/2009
Facility
- Application
- Chemical industry
- Sub-application
- Chlorine production
- Hydrogen supply chain stage
- All components affected
electrolyser cells
- Process temperature range [C]
- Above ambient temperature (50°C to 100°C)
- Location type
- Confined
- Location
- industrial area
- Operational condition
- Pre-event occurrences
A short circuit ignite a mixture of oxygen and hydrogen in an electrolyser cell.
Emergency & Consequences
- Number of fatalities
- 0
- Number of injured persons
- 0
Lesson Learnt
- Corrective Measures
After the accident, the plant operator put in place a system of monitoring and control of the process performed by on-site teams.
This measure was completed later by the installation of an automatic alarm system. Finally, a study was performed to increase the reliability of the whole monitoring system of the installation.
In-depth data
- Release type
- gas mixture
- Involved substances (% vol)
- H2, O2
- Release temperature [°C]
- 25
- Probable IGNITION SOURCE
- Explosion type
- Deflagration
References
- Sources categories
- ARIA
- Reference & weblink
Event description in the French database ARIA
https://www.aria.developpement-durable.gouv.fr/accident/25777/
(access September 2020)