Skip to main content
Clean Hydrogen Partnership

Explosion in a chemical plant, caused by accidental formation of hydrogen

Event

Event ID
832
Quality
Description

In a chemical plant, an explosion took place during the batch production of a stimulant drug (clobenzorex). The feedstock was an aqueous solution of sodium borohydride (NaBH4) supplied by a feed tank on a movable truck. At the basis of the explosion was the accidental production of hydrogen in the feed tank, due to a runaway chemical reaction enabled by excessive heating of the NaBH4.

The workshop was partially destroyed, and a technician was injured.

DETAILED ACCIDENT SEQUENCE
The NaBH4 solution (44 kg of powder for 130 kg of solution) was prepared 2 hours before production in a closed 630 litre agitated feed tank. Since dissolving was problematic, the operating mode had been recently modified to include pre-heating of the solution by hot water surface flow (45- 55°C).
14:00 The reactor was placed under nitrogen circulation (N2) and connected to the feed tank whose heating was stopped.
14.15 The N2 inlet of the feed tank was connected to the supply hose.
14:20 The N2 supply to the feed tank started with the partial opening of the supply valves of the reactor and the valves at the bottom of the feed tank (at a flow rate of 100 l/h – P(N2) = 2.8 bar).
14:40 The N2 hose supplying the feed tank was abruptly torn out letting the gas escape though the opening. The superfluous staff was evacuated from the workshop and an emergency team installed a valve on the N2 inlet to stop the leak. The team tried to decompress the feed tank in the reactor by opening the reactor valve to the maximum and opening the feed tank valve that was difficult to access.
At this moment, the feed tank’s manhole failed a few seconds before it exploded.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
Macro-region
Europe
Country
France
Date
Component involved
chemical storage tank
Failure mode
rupture & ignition
Initiating cause
run-away reaction
Root CAUSE analysis

The INITIATING CAUSE was the explosion of a flammable mixture inside the tank, due to the accidental formation of hydrogen.
Post-accident investigations revealed a thermal decomposition of sodium borohydride triggered by an excessively high storage temperature (50 °C due to hot water surface flow). Maintaining the temperature at 50 °C stabilised the decomposition rate in such a way that the small quantities of hydrogen formed could escape via the leaking feed tank.

When the heating was stopped, the reaction evolved in a self-sustaining mode: temperature and pressure increased under the effect of heat resulting from the decomposition, causing a thermal explosion. The inspection hole opened under a pressure of 15 to 20 bar followed by the rupture of the feed tank. The depressurisation of hydrogen in the form of a shock wave was responsible for the damage caused in the workshop.
The ROOT CAUSES were a poor knowledge of the properties of theNaBH4, the absence of a critical analysis of the process and of the effect of its modifications (management of changes) and failing of considering typical production incidents consequences.

Root causes
Date entry in HIAD
01/01/2020

Facility

Application
Chemical industry
Sub-application
chlorobenzorex production
Hydrogen supply chain stage
All components affected

Tank with an aqueous solution of sodium borohydride

Process temperature range [C]
Above ambient temperature (50°C to 100°C)
Location type
Confined
Location
industrial area
Operational condition
Description of the facility/unit/process/substances

From Wikipedia [https://en.wikipedia.org/wiki/Clobenzorex]:
Clobenzorex is a commercial product: a stimulant of the central nervous system and an anorectic drug, chemically classified as an N-substituted amphetamine and a phenethylamine.
Condensation between amphetamine and 2-chlorobenzaldehyde gives a Schiff-base. Subsequent reduction with NaBH4 completes the synthesis of clobenzorex.
(accessed Feb 2026)

Emergency & Consequences

Number of fatalities
0
Number of injured persons
1
Post-event summary

The workshop was devastated: roof ripped out, light walls displaced, solvent pipes ruptured by the projections. The feed tank was destroyed but the remaining process equipment was not damaged. Outside the workshop but near a door, a technician was projected against the containers by the shock wave. He sustained injuries on the ribs and was hospitalised for a month.

Emergency action

The superfluous staff was evacuated from the workshop and an emergency team installed a valve on the N2 inlet to stop the leak. The team tired to decompress the feed tank in the reactor by opening the reactor valve to the maximum and then opening the feed tank valve that was difficult to access. At this moment, the feed tank’s manhole gave in a few seconds before it exploded.

Lesson Learnt

Lesson Learnt

The system had been modified recently modified to improve the dissolution into water of a chemical compound. The modification consisted in pre-heating the solution. Among the several contributing causes, the absence of a critical analysis of the effect of the modifications is probably the one deserving the most the name of root cause. The plant operator failed to set up an effective management of changes and consider the whole of the unit in term of hazards and risks.

In-depth data

Release type
Gas-liquid mixture
Involved substances (% vol)
H2,
NaBH4 (solution)
Release temperature [°C]
50
Probable IGNITION SOURCE
Explosion type

References

Sources categories
ARIA
Reference & weblink

ARIA data base event no. 9841
https://www.aria.developpement-durable.gouv.fr/accident/9841/
(accessed Feb 2026)