Explosion in a aluminium manufacturing plant

Event

Event ID
1250
Quality
Description

A explosion occurred in the gas and dust treatment system for the aluminium holding furnaces at a metallurgical plant. The explosion caused the failure of the treatment system, the operation of the production lines without gas treatment resulted in the release of chlorine and chlorinated compounds into the atmosphere, as well as dust containing aluminium and zinc particles in various chemical forms.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
Macro-region
Europe
Country
France
Date
Component involved
treatment system (gas / fume / dust)
Failure mode
rupture & ignition
Initiating cause
run-away reaction
Root causes
Date entry in HIAD
25/12/2025

Facility

Application
Steel and metals industry
Sub-application
Al metallurgy
Hydrogen supply chain stage
Process temperature range [C]
ambient temperature (-50°C to +50°C)
Location type
Open
Location
populated area
Operational condition
Description of the facility/unit/process/substances

DESCRIPTION OF THE GAS & DUST TREATMENT SYSTEM
The gas treatment system consisted of a hydraulic treatment zone designed to suppress dust. The gas flow passed through a venturi system composed of two water spray nozzles. The gases and fumes then pass through a demister and are subsequently sent by a fan to a scrubbing tower. Within this tower, a caustic soda solution is diffused by a system of four nozzle arrays to remove chlorine compounds present in the fumes. These fumes are then sent to a second demister and then to an electrostatic precipitator.

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0

Lesson Learnt

Corrective Measures

Following the accident, the plant operator introduced these modifications:
(1) Adoption of a procedure for weekly tests aiming at detecting fouling or clogging of the suction ducts.
(2) Modifications to the automation program, to be able to shut down the gas purification system upon detection of high temperatures.
(3) Installation of a vacuum relief valve upstream of the fan, and of a flow meter upstream of the electrostatic precipitator with an alert threshold.
(4) Installation of a webcam in the room for verification purposes.
(5) Implementation of a lockout/tagout procedure, to prevent access to the room while the system was operating.

In-depth data

Release type
gas-dust mixture
Involved substances (% vol)
H2
NaOH
aluminium dust
Release temperature [°C]
25
Probable IGNITION SOURCE
Explosion type

References

Sources categories
ARIA
Reference & weblink

Event nr 50150 of the French database ARIA
https://www.aria.developpement-durable.gouv.fr/accident/50150/
(accessed December 2025)