Skip to main content
Clean Hydrogen Partnership

Detection of hydrogen release

Event

Event ID
401
Quality
Description

During a filling at a hydrogen refuelling station, the station was shut down due to a gas detection. The leak was extremely small and difficult to locate but the gas was directed upwards towards the gas sensor which shut down the station. The safety equipment performed well as it should and safely shutdown the station. The tiny leak was located about 8 cm from the end fitting in the middle of the hose.

Discovered during inspection.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
Europe
Country
Norway
Date
Component involved
dispenser (hose)
Failure mode
leak, no ignition
Initiating cause
material degradation (generic)
Root CAUSE analysis

It is suspected that the hose failure was due to an extreme temperature swing. It was the first really cold weather we had experienced being between -15 and -18c. The hose was sent back to the manufacturer for testing and no leak was found which was very interesting. The cause was never officially determined but the problem was resolved.

Root causes
Date entry in HIAD
01/01/2017

Facility

Application
Hydrogen refuelling station
Sub-application
Hydrogen dispenser
Hydrogen supply chain stage
All components affected

High pressure dispenser hose

Process temperature range [C]
ambient temperature (-50°C to +50°C)
Location type
Unknown
Location
unknown
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Emergency action

All safety equipment operated as designed and shut the system down.

Lesson Learnt

Lesson Learnt

All safety equipment operated as designed and shut the system down. In fact, if it were not for the hydrogen released, this could be classified as near-miss. Hoses are consumable parts; they damage quickly because they experience frequent pressure cycles characterised by very high pressures differences and temperature gradients. Moreover, they are also subjected to external mechanical stress such as bending and twisting during the filling.

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Release temperature [°C]
25
Probable IGNITION SOURCE

References

Sources categories
Investigation report
Reference & weblink

Source lost