Conventional fire on a CGH2 trailer

Event

Event ID
1139
Quality
Description

Early in the morning a hydrogen tube trailer experienced a tire fire and pulled onto the road shoulder. The driver attempted to extinguish the fire with the fire extinguisher on the vehicle. Heat from the fire caused seats on the isolation valves of two tubes to deform and the welded stainless steel manifold to crack, releasing hydrogen, ignited then by the tire fire.
The driver was unable to extinguish the fire and called the emergency number. Emergency responders closed the highway in both directions for several hours.
There were 2 injuries, the material damage was limited to the trailer.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
fire
Macro-region
North America
Country
United States
Date
Component involved
valve (generic)
Failure mode
rupture & ignition
Initiating cause
conventional component failure (fire)
Root CAUSE analysis

The INITIATING CAUSE was a conventional fire on tire following brake failure.
The ROOT CAUSE can be probably related to ageing of the tires or of the brake system. Maintenance procedures are in place to avoid these hazards. Moreover, tube protection from conventional fires seems having been not very effective (design shortcoming).

Root causes
Date entry in HIAD
25/10/2024

Facility

Application
Hydrogen transport and distribution
Sub-application
CGH2 tube trailer
Hydrogen supply chain stage
All components affected

tire, Piping, Fittings

Process temperature range [C]
ambient temperature (-50°C to +50°C)
Process pressure range [MPa]
medium to high pressure (10 to 50 MPa)
Location type
Open
Location
highway or similar
Operational condition
Pre-event occurrences

the refilled trailer had just been connected to the customer pressure reducing station

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Currency
US$
Property loss (onsite)
131.000
Post-event summary

no fatalities, no injuries, and damage was limited to the trailer

Emergency action

The driver tried to extinguish the fire by means of the extinguisher available on-board. Sine he did not succeed, the driver called the emergency responders which closed the highway in both directions for several hours.
The strategy adopted in regard of the fire is unknown.

Lesson Learnt

Lesson Learnt

The conventional brake fire which started this incident did not produce a heat input to the CGH2 tubes to cause their internal pressure to raise above the limit set by the pressure relief system. The burst disc did not open. The only damage caused by the fire was to a seal fitting, which caused a leak with limited consequences.
Nevertheless, other cases started with conventional fires caused the venting of the whole hydrogen load, because the pressure relief valve were thermally or pressure-activated. Such a scenario has to be avoided when the trailers are in a confined space, such as a tunnel.

Corrective Measures

The company investigated the possibility to replace the decking on the floor above the tires, now made of a aluminium plate, with a steel plate. The outcome of this analysis is unknown.

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Released amount (kg)
56
Release temperature [°C]
25
Release pressure [MPa]
18.6
Probable IGNITION SOURCE

References

Sources categories
PHMSA
Reference & weblink

Incident I-2011060207 of the US Pipeline and Hazardous Materials Safety Administration PHMSA:
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages&PortalPath=%…
(accessed September 2024)