Event
- Event ID
- 1139
- Quality
- Description
Early in the morning a hydrogen tube trailer experienced a tire fire and pulled onto the road shoulder. The driver attempted to extinguish the fire with the fire extinguisher on the vehicle. Heat from the fire caused seats on the isolation valves of two tubes to deform and the welded stainless steel manifold to crack, releasing hydrogen, ignited then by the tire fire.
The driver was unable to extinguish the fire and called the emergency number. Emergency responders closed the highway in both directions for several hours.
There were 2 injuries, the material damage was limited to the trailer.- Event Initiating system
- Classification of the physical effects
- Hydrogen Release and Ignition
- Nature of the consequences
- fire
- Macro-region
- North America
- Country
- United States
- Date
- Component involved
- valve (generic)
- Failure mode
- rupture & ignition
- Initiating cause
- conventional component failure (fire)
- Root CAUSE analysis
The INITIATING CAUSE was a conventional fire on tire following brake failure.
The ROOT CAUSE can be probably related to ageing of the tires or of the brake system. Maintenance procedures are in place to avoid these hazards. Moreover, tube protection from conventional fires seems having been not very effective (design shortcoming).- Root causes
- Date entry in HIAD
- 25/10/2024
Facility
- Application
- Hydrogen transport and distribution
- Sub-application
- CGH2 tube trailer
- Hydrogen supply chain stage
- All components affected
tire, Piping, Fittings
- Process temperature range [C]
- ambient temperature (-50°C to +50°C)
- Process pressure range [MPa]
- medium to high pressure (10 to 50 MPa)
- Location type
- Open
- Location
- highway or similar
- Operational condition
- Pre-event occurrences
the refilled trailer had just been connected to the customer pressure reducing station
Emergency & Consequences
- Number of fatalities
- 0
- Number of injured persons
- 0
- Currency
- US$
- Property loss (onsite)
- 131.000
- Post-event summary
no fatalities, no injuries, and damage was limited to the trailer
- Emergency action
The driver tried to extinguish the fire by means of the extinguisher available on-board. Sine he did not succeed, the driver called the emergency responders which closed the highway in both directions for several hours.
The strategy adopted in regard of the fire is unknown.
Lesson Learnt
- Lesson Learnt
The conventional brake fire which started this incident did not produce a heat input to the CGH2 tubes to cause their internal pressure to raise above the limit set by the pressure relief system. The burst disc did not open. The only damage caused by the fire was to a seal fitting, which caused a leak with limited consequences.
Nevertheless, other cases started with conventional fires caused the venting of the whole hydrogen load, because the pressure relief valve were thermally or pressure-activated. Such a scenario has to be avoided when the trailers are in a confined space, such as a tunnel.- Corrective Measures
The company investigated the possibility to replace the decking on the floor above the tires, now made of a aluminium plate, with a steel plate. The outcome of this analysis is unknown.
In-depth data
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Released amount (kg)
- 56
- Release temperature [°C]
- 25
- Release pressure [MPa]
- 18.6
- Probable IGNITION SOURCE
References
- Sources categories
- PHMSA
- Reference & weblink
Incident I-2011060207 of the US Pipeline and Hazardous Materials Safety Administration PHMSA:
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages&PortalPath=%…
(accessed September 2024)