Continuous release in open atmosphere

Event

Event ID
639
Quality
Description

An operator on patrol discovered a flame coming from the heat exchanger flange of a gasoline hydrodesulphurisation plant and reported it. The plant was immediately shut down.
An investigation revealed that the bolts on the flange were not properly tightened, causing the release of gasoline and hydrogen and their ignition.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
fire
Macro-region
Asia
Country
Japan
Date
Component involved
heat exchanger (flange)
Failure mode
leak & ignition
Initiating cause
loss of tightness
Root CAUSE analysis

The INITIATING CAUSE was loss of tightness of a flange due to loose bolts, for an unknown reason (by proxy, the reason could be loosening by thermal cycling).
The ROOT CAUSE could be attributed to incorrect tightening of the bolts during installation, which was not able to compensate for the differential thermal expansion of bolts and flange.

Root causes
Date entry in HIAD
01/05/2025

Facility

Application
Petrochemical industry
Sub-application
Hydrodesulphurisation process
Hydrogen supply chain stage
All components affected

Flange, heat exchanger

Process temperature range [C]
High temperature (100°C to 500°C)
Process pressure range [MPa]
medium to high pressure (10 to 50 MPa)
Location type
Unknown
Location
industrial area
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0

In-depth data

Release type
gas mixture
Involved substances (% vol)
H2
gasoline
Probable IGNITION SOURCE

References

Sources categories
KHK
Reference & weblink

High Pressure Gas Accident Cases Database of the KHK (High Pressure Gas Safety Association):
https://www.khk.or.jp/public_information/incident_investigation/hpg_inc…