Skip to main content
Clean Hydrogen Partnership

Collison with vehicle

Event

Event ID
406
Quality
Description

A car was driving out of the parking and hit the fuel cell bus at the rear (on the right-hand side).
Because of the slow speed of the fuel cell bus and the low speed of the car, only the body of the fuel cell bus and the car were damaged.

Event Initiating system
Classification of the physical effects
No Hydrogen Release
Nature of the consequences
Macro-region
Europe
Country
Switzerland
Date
Component involved
FCEV bus
Failure mode
damage, no release
Initiating cause
impact, rollover, crash
Root CAUSE analysis

The INITIATING CAUSE was a small road incident
The ROOT CAUSE was a human error.

Root causes
Date entry in HIAD
01/01/2017

Facility

Application
Road vehicles
Sub-application
FCEV-bus
Hydrogen supply chain stage
All components affected

FCEV bus, private car

Process temperature range [C]
ambient temperature (-50°C to +50°C)
Process pressure range [MPa]
medium to high pressure (10 to 50 MPa)
Location type
Unknown
Location
populated area
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0

In-depth data

Release type
no release
Released amount (kg)
0
Release temperature [°C]
25
Probable IGNITION SOURCE

References

Sources categories
Investigation report
Reference & weblink

Provided to JRC by the operator of the facility