Skip to main content
Clean Hydrogen Partnership

Bolts rupture due to hydrogen embrittlement

Event

Event ID
175
Quality
Description

The bolts on a flange, at a not further specified industrial facility failed after approximately 4000 hours in service (approximately 18 months in service). Their failure caused H2S leaks.
The bolts fractured as a result of a hydrogen embrittlement mechanism (Hydrogen Stress Cracking) in a H2S rich atmosphere and in presence of humidity.

Event Initiating system
Classification of the physical effects
n.a.
Nature of the consequences
n.a.
Macro-region
Europe
Country
Spain
Date
Component involved
flange (bolts)
Failure mode
rupture, no ignition
Initiating cause
H2-driven material degradation
Root CAUSE analysis

The cause was a material/component failure due to hydrogen embrittlement (Sulphide Stress Cracking). The steel used for the bold belonged to a martensitic steel family which is not advised for use for continuous operation with wet H2S. The ROOT CAUSE could be attributed to a design failure.

Root causes
Date entry in HIAD
28/02/2009

Facility

Application
Unknown
Sub-application
unknown
Hydrogen supply chain stage
All components affected

Bolts

Location type
Unknown
Location
unknown
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0

Lesson Learnt

Lesson Learnt

The specific hydrogen-related damage causing the rupture of the bolts is known as Sulphide Stress Cracking (SSC). In first instance, the steels react with hydrogen sulphide (H2S), forming metal sulphides (MeS) and atomic hydrogen as corrosion byproducts.
SSC is basically a hydrogen embrittlement phenomenon, in which atomic hydrogen penetrates in the steel cracking it. It is a mechanism susceptible to occur when 3 circumstances take place simultaneously: a susceptible material, a brittle atmosphere (H2S) and a sufficient maintained level of stresses. It is a mechanism that can happen under mechanical loads of remarkably lower magnitudes than the elastic limit of the material, being able to be sufficient the own residual stresses of manufacturing or assembly. Susceptibility to hydrogen embrittlement of steels is as much greater as it is its mechanical resistance or hardness, a reference value of 26 HRC being used for martensitic stainless steels with quenching and tempering thermal treatment (In this case, bolts had a hardness 48 HRC).

In-depth data

Release type
gas
Involved substances (% vol)
H2S 100%
Probable IGNITION SOURCE

References

Sources categories
Unknown
Reference & weblink

source lost