Fire on a fuel cell stack in a testing laboratory

Event

Event ID
1259
Quality
Description

Due to a due a leak of hydrogen at the manifold, a hydrogen fuel cell stack caught fire and burned at a testing laboratory. Since the safety interlocks had been unintentionally turned off during the test, the safety automation system did not activated.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
fire
Macro-region
Europe
Country
Finland
Date
Component involved
other
Failure mode
leak
Initiating cause
wrong operation
Root CAUSE analysis

The INITIATING CAUSE was the fact that the manifold was not properly sealed and caused a hydrogen leak during fuel cells testing. 

The user/operator failed to notice the irregularity during operation, partially due to the absence of any alerts. There was a an automatic  shutdown system activating on high H2 concentration values and low fuel cell voltages, but its interlock supposed to intervene was switched off, and therefore the emergency shutdown did not happen. These elements suggest a ROOT CAUSE related to failure in following the procedures and in shortcoming of management in overviewing and guaranteeing the correct execution of the safety procedures. 

Root causes
Date entry in HIAD
25/08/2026

Facility

Application
Laboratory / R&D
Sub-application
Fuel cell testing station
Hydrogen supply chain stage
All components affected

stationary PEMFC

Process temperature range [C]
Above ambient temperature (50°C to 100°C)
Process pressure range [MPa]
low to medium pressure (below 2 MPa)
Location type
Confined
Location
other
Operational condition
Description of the facility/unit/process/substances

hydrogen fuel cell lab - hydrogen fuel cell test rig

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Environmental damage
0

Lesson Learnt

Corrective Measures
  • Ensure user’s comprehension of the test station. Training for the users of the test station should be done more comprehensively, including automation and troubleshooting.
  • H2 sensor should shut down the main hydrogen and air valve right away, and it shall not be possible be deactivated it at any condition.
  • A minimum program safety should measure and make use of temperature, pressure, and minimum cell voltage.
  • An alert shall activate in case the system is operated in absence the safety systems.
  • An alert shall activate when the load is on in absence the safety systems.
  • An automatic nitrogen purge shall start in the event of e-shutdown
  • A maximum exhaust fan speed and exhaust duct at proximity of the testing rig are required

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Probable IGNITION SOURCE

References

Sources categories
HIAD reporting system