Event
- Event ID
- 1181
- Quality
- Description
An explosion occurred in the venting system of a metal grinding CNC-unit. The explosion has been attributed to the unexpected reaction between the water used for the cooling of the grinding and the powder produced by the unit, with the production of hydrogen. The powder consisted in aluminium, magnesium and silicium.
The local fire brigade intervened (6 vehicles and 27 persons). The clearing of the emergency required to extract the hydrogen-air mixture from the venting system. The fire department deployed an explosion-proof suction device.
Nobody was injured.- Event Initiating system
- Classification of the physical effects
- Hydrogen Release and Ignition
- Nature of the consequences
- Macro-region
- Europe
- Country
- Austria
- Date
- Component involved
- venting system
- Failure mode
- rupture & ignition
- Initiating cause
- accidental hydrogen formation
- Root CAUSE analysis
The INITIATING CAUSE was the unintended hydrogen production from a reaction between metal powder and cooling water.
The ROOT CAUSE cannot be identified (yet). It can be assumed that this was a unique case, and that the unit had worked before without this type of incidents. It is unknown if and which modifications to the usual process could have brought to the electrolysis of water in presence of dust.
- Root causes
- Unknown
- Date entry in HIAD
- 30/08/2025
Facility
- Application
- Steel and metals industry
- Sub-application
- metal grinding
- Hydrogen supply chain stage
- All components affected
grinding machine
- Location type
- Confined
- Location
- industrial area
- Operational condition
Emergency & Consequences
- Number of fatalities
- 0
- Number of injured persons
- 0
- Post-event summary
Nothing known on the amount of damage. Probably, only the vent duck or system was affected.
- Emergency action
The local fire brigade intervened (6 vehicles and 27 persons).
The clearing of the emergency required to extract the hydrogen-air mixture, from the venting system. The fire department deployed an explosion-proof suction device. Using a hand diaphragm pump and suitable tools, several hundred litres of fluid were extracted and drained. It took more than three hours for the fire department to regain operational readiness.
Lesson Learnt
- Lesson Learnt
No specific Lesson Learnt possible, in absence of details on the process, its procedures, the possible changes occurred on the day of the incident and the process parameters. It is known that very fine metal powder, possibly in a dust cloud, is very reactive to explosive oxidation. The assumption made by the fire brigade to explain the explosion is the occurrence of an oxidation reaction between water and the metallic powder, with production of hydrogen which then ignited and exploded. The report, however, does not mention a direct confirmation of presence of hydrogen.
In-depth data
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Probable IGNITION SOURCE
- Explosion type
References
- Sources categories
- News
- Reference & weblink
News at
https://www.5min.at/5202405131641/chemieunfall-in-ligist-brachte-feuerw…
(accessed August 2025)