Event
- Event ID
- 1120
- Quality
- Description
A LH2 trailer had just delivered hydrogen to a customer and was travelling on a highway returning to the base, when the driver noticed that the pressure inside the tank was increasing rapidly.
The driver stopped at a rest stop to report incident. Local fire-fighters departments and the trailer company responded. The fire-fighters evacuated the rest stop area. Meanwhile, the trailer was venting hydrogen and reducing the internal pressure with no further problems. The cause appeared to be a mechanical problem, possibly a loss of vacuum on the vessel.- Event Initiating system
- Classification of the physical effects
- Unignited Hydrogen Release
- Nature of the consequences
- leak no ignition
- Macro-region
- North America
- Country
- United States
- Date
- Component involved
- PRD (generic)
- Failure mode
- rupture, no ignition
- Initiating cause
- over-pressurisation (thermal insulation degradation)
- Root CAUSE analysis
The INITIAL CAUSE was over-pressurisation of the LH2 tank, which triggered a hydrogen venting.
The ROOT CAUSE was probably due to a loss of the thermal insulation capacity of the tank, due to some mechanical events which partially disrupted the annular vacuum between the external and internal shells of the LH2 tank.- Root causes
- Date entry in HIAD
- 09/09/2024
Facility
- Application
- Hydrogen transport and distribution
- Sub-application
- LH2 tanker
- Hydrogen supply chain stage
- All components affected
vacuum thermal insulation
- Process temperature range [C]
- cryogenic temperature (below -50°C)
- Process pressure range [MPa]
- low to medium pressure (below 2 MPa)
- Location type
- Open
- Location
- highway or similar
- Operational condition
- Pre-event occurrences
The driver had terminated the delivery of LH2 to a customer's site. It can be assumed that the trailer was (almost) empty.
Emergency & Consequences
- Number of fatalities
- 0
- Number of injured persons
- 0
- Currency
- US$
- Property loss (onsite)
- 0
- Post-event summary
None
- Emergency action
The local fire-fighters departments and the trailer company responded. The fire-fighters evacuated the rest stop area of the highway where the trailer was parked. Although not stated explicitly, it can be assumed that the emergency team strategy was to let the trailer venting till stabilisation of the internal pressure. It was anyhow almost empty.
In-depth data
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Probable IGNITION SOURCE
References
- Sources categories
- PHMSA
- Reference & weblink
Incident I-2004061465 of the US Pipeline and Hazardous Materials Safety Administration PHMSA:
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages&PortalPath=%…
(accessed September 2024)