Dispenser nozzle freezing during hydrogen refuelling

Event

Event ID
1038
Quality
Description

This entry refer to a series of events occurred before the date given, which corresponds to the publication of the evidences at the Int. Conference on Hydrogen Safety 2015.
The nozzle/receptacle connection froze when refuelling the on-board hydrogen storage system at the lowest precooling temperature of -40 C.
However, freezing did not cause apparatus damage nor hydrogen leakage. The nozzle/receptacle is thus able to fuel safely even if the nozzle/receptacle is stuck due to ice.

Event Initiating system
Classification of the physical effects
No Hydrogen Release
Nature of the consequences
Macro-region
Asia
Country
Japan
Date
Component involved
dispenser (nozzle)
Failure mode
n.a.
Initiating cause
ice formation
Root CAUSE analysis

The low temperature of the hydrogen caused the water vapour in the atmosphere to freeze around the nozzle-receptacle connection. Under specific environmental conditions creating high humidity, the quantity of ice forming does not allow for decoupling of the connection after the refuelling.

Root causes
Date entry in HIAD
01/06/2023

Facility

Application
Hydrogen refuelling station
Sub-application
Hydrogen dispenser
Hydrogen supply chain stage
All components affected

nozzle - receptacle connection

Process temperature range [C]
ambient temperature (-50°C to +50°C)
Location type
Open
Location
populated area
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Post-event summary

Despite the impossibility to decouple the connection, no damage is caused to the components. It is enough to wait for de-icing.

Emergency action

It would be enough to wait for the melting of the ice.

Lesson Learnt

Lesson Learnt

Under certain environmental conditions, air humidity can precipitate as ice around the nozzles/receptacle connection.
The results of the research presented at the ICHS2015 confirmed that the possibility of hydrogen leakage or damage to the apparatus during nozzles/receptacle connection freezing is low and that it is safe. Freezing at the hydrogen station will only prolong fuelling time.

Corrective Measures

The standards prescribing nozzle - receptacle designs were adapted.

In-depth data

Release type
no release
Release temperature [°C]
25
Probable IGNITION SOURCE

References

Sources categories
Scientific article
Reference & weblink

paper 346 presented at the Int. Conference onHydrogenSafety ICHS2015