Description

An explosion occurred in a graphite purification workshop. Due to a leak of the cooling circuit of an electric furnace, the water entered in contact with materials at a temperature of 1,800°C. The gas mixture produced (hydrogen, air...) exploded. The carbon contained in the furnace was ejected and ignited as well.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
Macro-region
Europe
Country
France
Date
Component involved
reactor / oven / furnace / test chamber
Failure mode
rupture & ignition
Initiating cause
accidental hydrogen entrance
Root CAUSE analysis

INITIATING CAUSE was the leaking of water into the high temperature reactor, which brought to water thermolysis.

Nothing is known on the reason for the leak.

Root causes
Unknown
Date entry in HIAD
01/01/2018

Facility

Application
Chemical industry
Sub-application
graphite production
Hydrogen supply chain stage
All components affected

graphite purification reactor

Process temperature range [C]
Ultra-high temperature (above 1000°C)
Location type
Confined
Location
industrial area
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Post-event summary

The furnace and the roof covering it were destroyed.

Emergency action

The local residents alert the fire brigade. The fire is extinguished with powder (including carbon).

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Release temperature [°C]
1800
Probable IGNITION SOURCE
Explosion type
Detonation

References

Sources categories
ARIA
Reference & weblink

Description of the event in the French database ARIA
https://www.aria.developpement-durable.gouv.fr/accident/10466/