Event
- Event ID
- 907
- Quality
- Description
A pallet containing 9 hydrogen cylinders was damaged during the operation of unloading the cylinders trailer by means of a forklift.
A 2 mm wide crack, caused by the fork, was observed on a flexible.
The fire brigade decided for an emergency and evacuation zone of 200 m.
The intervention of an expert allowed to measure a remaining pressure in the pallet of 100 bar. He tightened a nut and stopped the leak after approximately 3 hours. The amount of hydrogen released was estimated at 30 m3.- Event Initiating system
- Classification of the physical effects
- Unignited Hydrogen Release
- Nature of the consequences
- leak no ignition
- Macro-region
- Europe
- Country
- France
- Date
- Component involved
- piping (generic)
- Failure mode
- rupture, no ignition
- Initiating cause
- impact, rollover, crash
- Root CAUSE analysis
INITIATING CAUSE was the damage of compressed hydrogen cylinders by a forklift. In absence of information on driver, the ROOT CAUSE is attributed generically to a human error (wrong manoeuvre).
The responsibility of the operative management in guaranteeing safety measure able to prevent or mitigate such an event is not evident but cannot be excluded either.- Root causes
- Date entry in HIAD
- 01/01/2018
Facility
- Application
- Hydrogen transport and distribution
- Sub-application
- CGH2 cylinders truck
- Hydrogen supply chain stage
- All components affected
cylinders
- Process temperature range [C]
- ambient temperature (-50°C to +50°C)
- Process pressure range [MPa]
- medium to high pressure (10 to 50 MPa)
- Location type
- Open
- Location
- highway or similar
- Operational condition
Emergency & Consequences
- Number of fatalities
- 0
- Number of injured persons
- 0
- Emergency action
The fire brigade decided for an emergency zone of 200 m. Workers of 20 companies were evacuated.
The traffic on neighbouring roads stopped.
Lesson Learnt
- Lesson Learnt
Better operative procedures used for the unloading process of compressed hydrogen bottles were required. The load/unloading process are the two operations most affected by hazards, in particularly the unloading of full bottles at the customer sites, where not always the required infrastructure is available.
In alternative, or addition, a better structural protection of the pressurised components of the pellet would increase the level of safety of those operations.
In-depth data
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Released amount (kg)
- 3
- Release temperature [°C]
- 25
- Release pressure [MPa]
- 20
- Probable IGNITION SOURCE
References
- Sources categories
- ARIA
- Reference & weblink
Event description in French database ARIA
https://www.aria.developpement-durable.gouv.fr/accident/1380/
(accessed September 2020)