Sulphuric acid reaction created hydrogen gas explosion.

Event

Event ID
753
Quality
Description

A dye beam operator was drawing concentrated sulphuric acid into a plastic pail. He added to this pail the contents of a "drip pail" which had been located under the 55 gallon acid drum. The pail started "smoking" and exploded a few seconds later, sending a plume of acid to the ceiling about 20 ft. Up. The operator and three other nearby employees and received skin burns when the acid rained down upon them. A fourth, further away, went to the hospital to have his ear plugs removed.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
Macro-region
North America
Country
United States
Date
Component involved
chemical storage tank (H2SO4)
Failure mode
internal explosion
Initiating cause
unknown
Root CAUSE analysis

The INITIATING CAUSE was formation of gaseous hydrogen from a reaction of sulphuric acid reaction with unspecified other substance (it is known that a reaction between a metal and H2SO4 produces H2).

Root causes
Date entry in HIAD
01/01/2020

Facility

Application
Chemical industry
Sub-application
Organic chemicals production
Hydrogen supply chain stage
All components affected

acid drum

Location type
Unknown
Location
industrial area
Operational condition
Pre-event occurrences

Unclear if the operation was part of the normal production cycle.

Emergency & Consequences

Number of fatalities
0
Number of injured persons
2

In-depth data

Release type
Gas-liquid mixture
Involved substances (% vol)
H2,
H2SO4
Probable IGNITION SOURCE
Explosion type
Deflagration

References

Sources categories
OHSA
Reference & weblink

Occupational Safety and Health Administration (OHSA)- Accident Summary Nr: 14265011