Skip to main content
Clean Hydrogen Partnership

Fire on a naphtha cracker

Event

Event ID
666
Quality
Description

A fire in a first stage 'pygas' (pyrolysis of gasoline) hydrogenation of a naphtha cracker was caused by escape of a mixture of gasoline, hydrogen and nickel catalyst through a crack in the wall of the reactor. Investigation showed that the crack was caused by a brief local temperature excursion, explained by a local disturbance and heat removal, attributed to a runaway reaction during the start-up (7 days previously) initiated by sudden increase in fresh feed added to the reactor. Excessive formation of carbon-like products impeded the liquid distribution.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
fire
Macro-region
Europe
Date
Component involved
reactor / oven / furnace / test chamber
Failure mode
rupture & ignition
Initiating cause
over-heating (run-away reaction)
Root causes
Unknown
Date entry in HIAD
01/01/2020

Facility

Application
Petrochemical industry
Sub-application
Hydrodesulphurisation process
Hydrogen supply chain stage
All components affected

cracker and reactors and reaction equipment

Location type
Unknown
Location
industrial area
Operational condition
UNKNOWN

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0

In-depth data

Release type
gas-solid mixture
Involved substances (% vol)
H2,
naphta,
nickel catalyst
Probable IGNITION SOURCE

References

Sources categories
ICHEME
Reference & weblink

Event description extracted from the UK database ICHEME in PDF.
The
https://www.icheme.org/knowledge/safety-centre/resources/accident-data/
(accessed October 2020)