Skip to main content
Clean Hydrogen Partnership

Explosion at a rocket centre

Event

Event ID
629
Quality
Description

An explosion occurred at a aerospace testing centre, while testing a liquid hydrogen turbo-pump, part of a rocket engine. On the day of the incident, seven seconds after the rotation speed of the pump had reached its steady state (45,000 rpm), excessive vibration was detected. The pump was stopped but a loud bang was heard. The operator started to inject nitrogen gas. One and a half minutes after the bang, flames were seen in front of the testing building, coming from burning cables.
Hydrogen gas discharged from the vent stack on a liquid hydrogen tank also caught fire.

[Note of HIAD validator: this report was orignally provided by the database RISCAD, now uanvailable. It is now in the KHK database (see references). Details are unclear, probablydue to the machine translation from Japanes. For example, the ignition of the H2 at the vent of a LH2 tank was reported only by RISCAD, not by KHK].

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
Macro-region
Asia
Country
Japan
Date
Component involved
cryogenic pump
Failure mode
leak & ignition
Initiating cause
unknown
Root CAUSE analysis

The INITIATING CAUSE was the damaging of the LH2 pump: the cam of the turbo pump broke, causing hydrogen gas to leak out.
ROOT CAUSE is unknown.

Root causes
Date entry in HIAD
01/01/2020

Facility

Application
Non-road vehicles
Sub-application
Aerospace
Hydrogen supply chain stage
All components affected

water pump, rocket engine, liquid hydrogen tank

Process temperature range [C]
cryogenic temperature (below -50°C)
Location type
Unknown
Location
unknown
Operational condition
Pre-event occurrences

A test was ongoing

Emergency & Consequences

Number of fatalities
0
Number of injured persons
1

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Probable IGNITION SOURCE
Explosion type

References

Sources categories
KHK
Reference & weblink

High Pressure Gas Accident Cases Database of the KHK (High Pressure Gas Safety Association):
https://www.khk.or.jp/public_information/incident_investigation/hpg_inc…
(accessed May 2025)

The first entry in HIAD was coming from RISCAD, which is now closed.