Fire in a benzene plant

Event

Event ID
623
Quality
Description

During repairs of a heat exchanger in a benzene plant, a mixed gas (methane and hydrogen) contained in the cold box attached to the exchanger leaked and caught fire from a welding spark. The exchanger was severely damaged by the fire.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
fire
Macro-region
Asia
Date
Component involved
heat exchanger (cold box)
Failure mode
leak & ignition
Initiating cause
wrong operation
Root CAUSE analysis

The ROOT CAUSE was the failure to close a valve with a blind plate, before starting the repairs. The cold box was not properly closed.

Root causes
Date entry in HIAD
01/01/2020

Facility

Application
Petrochemical industry
Sub-application
Benzene production
Hydrogen supply chain stage
All components affected

Heat exchanger

Location type
Unknown
Location
industrial area
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Post-event summary

The exchanger was severely damaged by the fire.

In-depth data

Release type
gas mixture
Involved substances (% vol)
H2, CH4
Probable IGNITION SOURCE

References

Sources categories
ICHEME
Reference & weblink

Event nr 10256 of the UK database ICHEME in PDF format.
https://www.icheme.org/knowledge/safety-centre/resources/accident-data/
(accessed October 2020)