Skip to main content
Clean Hydrogen Partnership

Fire at a refinery

Event

Event ID
578
Quality
Description

A fire occurred in a hydrogen and catalyst loading line of heavy oil unit. The most likely cause was that a hydrogen purge pipeline failed allowing hydrogen to escape. This mixed with hot oil bringing the temperature to approximately 825 degrees F (441 degrees C), i.e. above the auto-ignition temperature.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
fire
Macro-region
Asia
Country
Kuwait
Date
Component involved
pipe (generic)
Failure mode
rupture & ignition
Initiating cause
unknown
Root causes
Unknown
Date entry in HIAD
01/01/2020

Facility

Application
Petrochemical industry
Sub-application
Catalytic reforming processes
Hydrogen supply chain stage
All components affected

hydrogen purge pipeline, catalyst loading lines of heavy oil unit

Process temperature range [C]
High temperature (100°C to 500°C)
Location type
Unknown
Location
industrial area
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Post-event summary

Fire

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Release temperature [°C]
440
Probable IGNITION SOURCE

References

Sources categories
ICHEME
Reference & weblink

Extract from the ICHEME database on equipment details