Event
- Event ID
- 571
- Quality
- Description
A truck carrying 6,000 gallons of liquid hydrogen (1,600 kg) experienced an accidental loss of confinement while travelling.
The truck driver noticed a white vapour cloud coming from the rear of his trailer and an increase in the internal vapour pressure gauge. he decided to stop the vehicle in an area he considered safe. The hydrogen did not ignited, only a plume of condensing water vapour was visible.
The firefighters were alarmed 10 minutes later. They decided to let the hydrogen to be released and to dissipate into the atmosphere. They closed the motorway and evacuated the neighbourhood. During the emergency, it became clear that the tank's inner lining had started failing and that the external shell was in direct contact with the liquid or cryogenic hydrogen.
This natural release process took 14 hours. The firefighters decided to call off the evacuation and reopened the motorway when the truck company experts communicated that they had released as much hydrogen as possible, and declared the situation safe.
Since the remaining liquid hydrogen in the tank had started building pressure in the tank, the tank was moved to an area considered safe, far away from power lines, which represent a fire risk, because of the increased possibility of ignition. The area was cleared and the truck was left there for the time required to declare the situation definitively safe.
[Note of the event validator: although the source does not say it, it can be assumed that before moving away the truck the relief valve was closed again, and that this caused the increase of internal pressure noticed. It is further logic to assume that after the tank was moved to the area considered safe, the valve was opened again to allow for further release and diffusion of the hydrogen still inside. However, it could exist an alternative explanation for the increase in pressure: the firefighters used water to warm up the tank and accelerate the venting of the residual hydrogen. This could have caused the freezing of the relief valve and blocked the venting].- Event Initiating system
- Classification of the physical effects
- Unignited Hydrogen Release
- Nature of the consequences
- leak no ignition
- Macro-region
- North America
- Country
- United States
- Date
- Component involved
- PRD (valve)
- Failure mode
- correct activation & venting
- Initiating cause
- over-pressurisation (thermal insulation degradation)
- Root CAUSE analysis
INITIATING CAUSE was the unexplained loss of vacuum between the inner vessel and outer vessel of the LH2 tank on the trailer, due probably to a weld failure.
ROOT CAUSE: it is impossible to identify a root cause different than a material degradation. This could be induced by a design fault or a damage occurred during operation.
- Root causes
- Date entry in HIAD
- 19/09/2024
Facility
- Application
- Hydrogen transport and distribution
- Sub-application
- LH2 tanker
- Hydrogen supply chain stage
- All components affected
cryogenic tank
- Process temperature range [C]
- cryogenic temperature (below -50°C)
- Process pressure range [MPa]
- low to medium pressure (below 2 MPa)
- Location type
- Open
- Location
- populated area
- Operational condition
- Pre-event occurrences
The truck was transporting hydrogen from the place of production to the place of use, along a approximately 1600 km long route. The incident happened at a location at 65 km from destination.
Emergency & Consequences
- Number of fatalities
- 0
- Number of injured persons
- 0
- Property loss (onsite)
- 0
- Post-event summary
The voluntary evacuation of a neighbourhood, including closure of the school, and closure of roads, which caused a gigantic traffic jam.
- Emergency action
A. The driver remarked a problem on the liquid hydrogen tank. Because of the drivers training in handling liquid hydrogen, he knew that he needed to position the tractor/trailer unit where it would cause the least amount of danger to the traffic and public. Therefore, he made the decision to exit the highway at the first available exit. This exit appeared to be a low volume traffic area at 5:30 in the morning, however, it was a main road connecting two cities.
B. The firefighters of a city nearby and the regional hazardous materials team were alarmed 10 minutes later. They decided to let the tank release the non-toxic hydrogen into the atmosphere and to avoid to contain the leak dissipate naturally. An alternative could have been to transfer the liquid hydrogen into a new tank. Unfortunately, the nearest tank for such an operation was 13 hours away.
They also decided to close the motorway and to evacuate the neighbourhood, including the schools. During the emergency, it became clear that the tank's inner shell had failed. Therefore, they concluded that it would have not been safe to move the trailer.
The release process took 14 hours. The firefighters decided to call off the evacuation and reopened the motorway when the truck company experts communicated that they had released as much hydrogen as possible, and declared the situation safe. Meanwhile, to accelerate the venting, firefighters applied water to warm the tanker.
Lesson Learnt
- Lesson Learnt
Critical technical information is missing in the event description, hindering the extraction of specific lessons. For example, the pressure relief system of the cryogenic tank is not provided, and therefore it is not possible to assess the decision by the driver to open a relief valve to mitigate the consequence of pressure oscillation in the tank.
The following general lesson can be attempted:
Despite the correct handling of the emergency by the first responders, they deployed a large amount of precaution measures, with the evacuation of the neighbourhood, an extensive closure of the local road transport and the intervention of the transport company engineers and governmental experts.
1. This is a sign that formalised procedures on how to handle massive transport of hydrogen were missing or were not enough specific. The knowledge on how to handle these cases should not remain inside the company perimeters, but broadly shared and agreed with local authorities and the first responders.
2. As in the case of transport of hazardous substances, these procedures should also consider the specific routes used by drivers, and minimise the need to drive through densely populated areas.
In-depth data
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Released amount (kg)
- 4290.6888720666
- Probable IGNITION SOURCE
References
- Sources categories
- PHMSA
- Reference & weblink
Incident I-2004010807 of the US Pipeline and Hazardous Materials Safety Administration PHMSA:
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages&PortalPath=%…
(accessed September 2024)The Register-Guard online news of 2003-09-16
https://www.thefreelibrary.com/Tanker+leak+ties+up+town.-a0110174822
(accessed September 2024)