Mechanical failure of a hydrogen compressor

Event

Event ID
548
Quality
Description

Discharge pressure of a hydrogen compressor on a chloride plant fell to alarm level without any prior warning. Simultaneously three bumps were heard.
Smoke was seen coming from the hot motor bearing and the machine had to be stopped manuall, because it had not tripped automatically. No external fire occurred and the hydrogen product was directed to the vent stackwhile the chlorine plant continued to run normally.
Examination of the compressor showed that the studs of the driven end first stage cylinder head had failed and subsequent examination of the piston rod showed that this had failed at the threaded attachment to the crosshead, the motor bearing showed severe heating by oil smoke and paint discoloration.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
Europe
Country
United Kingdom
Date
Component involved
compressor / booster / pump (piston)
Failure mode
rupture, no ignition
Initiating cause
material degradation (fatigue)
Root CAUSE analysis

The INITIATING CAUSE was the failure of the compressor piston due to fatigue, under conditions which worsened the consequence.

The post-incident investigation reached the following conclusions:
1. The piston rod failed by fatigue initiated at the crosshead end threads.
2. No evidence was found of any individual error in assembly or operation which contributed directly to the initiation of this incident.
3. Indications are that the vibration trip system was not in function at the time of this piston rod failure, increasing the secondary damage at the motor and resulting in the provision of a possible ignition source for the escaping hydrogen.
4. The damage to the compressor indicated that both the compressor and the driver motor, acting as a flywheel, may have been subjected to extreme impulsive forces, with possible damage being caused to frames or shafts. However, subsequent inspections did show distortions to be negligible, and no cracks have been detected.
5. There was some evidence that liquid passes into this compressor in sufficient quantities under some conditions to cause mechanical distress.

The ROOT CAUSE is unknown.

Root causes
Unknown
Date entry in HIAD
01/01/2020

Facility

Application
Chemical industry
Sub-application
Chlorine production
Hydrogen supply chain stage
All components affected

hydrogen compressor

Process temperature range [C]
Above ambient temperature (50°C to 100°C)
Location type
Confined
Location
unknown
Operational condition
Description of the facility/unit/process/substances

COMPRESSOR COMPONENT WHICH FAILED
A crosshead in a gas compressor is a reciprocating component that connects the piston rod to the connecting rod, acting as a sliding joint to convert rotational crankshaft motion into purely linear motion. It slides within guides to manage side loads and prevent lateral forces from bending the piston rod, reducing wear on cylinder liners and packing.
[Google Gemini answer, 11/04/2026]

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Post-event summary

No external fire occurred and the hydrogen product was out to stack.
The chlorine plant continued to run as required.

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Release temperature [°C]
25
Probable IGNITION SOURCE

References

Sources categories
ICHEME
Reference & weblink

Event nr 9426 extracted from the UK database ICHEME in PDF format.
https://www.icheme.org/knowledge/safety-centre/resources/accident-data/
(accessed October 2020)