Over-pressurisation of a LH2 tanker

Event

Event ID
527
Quality
Description

A liquid hydrogen tanker was travelling back to the base after having made an earlier delivery. At the end of the delivery, the pressure in the tanker had been reduced to 75 psig using the vent stack installed at the customer unit.
During a routine stop to conduct a check of the tires and of the tank pressure, the drivers noted that the pressure had risen to 138 psig (9.5 barg), in excess of the anticipated pressure rise for a hydrogen tanker. To prevent any unexpected venting of hydrogen gas, they exited the highway and stopped at an abandoned gas station. There the drivers ("blew down") reduced manually the tank pressure to 75 psig (5.2 barg) and restarted the travel. When the tanker had travelled for approximately 6 hr, the pressure had climbed back to 120 psig (8.3 barg). It is not mentioned in the report, but it is probable that the drivers decided to repeat the blow down procedure before arriving at the home terminal (probably at additional 3 hr driving).
The trailer was removed from service because of the deterioration of the vacuum of the thermal insulation shell.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
North America
Country
United States
Date
Component involved
LH2 tank (road tanker)
Failure mode
manual venting
Initiating cause
over-pressurisation (thermal insulation degradation)
Root CAUSE analysis

The INITIAL CAUSE was over-pressurisation of the LH2 tank, which caused an intervention of the drivers to reduce pressure.
The ROOT CAUSE was the degradation of the thermal insulation capacity of the tank.

Root causes
Date entry in HIAD
01/01/2020

Facility

Application
Hydrogen transport and distribution
Sub-application
LH2 tanker
Hydrogen supply chain stage
All components affected

vacuum thermal insulation

Process temperature range [C]
cryogenic temperature (below -50°C)
Process pressure range [MPa]
low to medium pressure (below 2 MPa)
Location type
Open
Location
highway or similar
Operational condition
Pre-event occurrences

The tanker was almost empty, after delivery.

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Currency
US$
Property loss (onsite)
0
Post-event summary

A negligible amount of hydrogen was released.

Emergency action

the driver exited the highway and stopped at an abandoned gas station. There the drivers ("blew down") reduced manually the tank pressure to 75 psig (5.2 barg) and restarted the travel.

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Release pressure [MPa]
0.62
Probable IGNITION SOURCE

References

Sources categories
PHMSA
Reference & weblink

Incident I-1997080401 of the US Pipeline and Hazardous Materials Safety Administration PHMSA:
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages&PortalPath=%…
(accessed September 2024)