Small release from a LH2 tanker

Event

Event ID
481
Quality
Description

A liquid hydrogen tanker was travelling to a customer when the driver noticed that hydrogen release was occurring at the trailer vent stack. The driver stopped the vehicle in a safe location and investigated the cause discovering that the vent valve had opened slightly. The driver could stop the venting by closing the valve tightly. The tanker could deliver at destination without further venting (total trip approximately 3 hours).
Back to the home terminal, an inspection found that a small amount of ice had most likely prevented full closure of the vent valve. This ice formation had occurred when equilibrating internal pressure before the start of the trip. When the ice melted during the travel, the vent opened slightly, resulting in a venting.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
North America
Country
United States
Date
Component involved
valve (generic)
Failure mode
rupture, no ignition
Initiating cause
ice formation
Root CAUSE analysis

The INITIAL CAUSE a not tight manual vent valve.
The ROOT CAUSE was the formation of ice during preparation of the load for the trip. This could hint at incomplete procedural guidelines.

Root causes
Date entry in HIAD
01/01/2025

Facility

Application
Hydrogen transport and distribution
Sub-application
LH2 tanker
Hydrogen supply chain stage
All components affected

vent Valve

Process temperature range [C]
cryogenic temperature (below -50°C)
Process pressure range [MPa]
low to medium pressure (below 2 MPa)
Location type
Open
Location
highway or similar
Operational condition
Pre-event occurrences

The LH2 tanker was full

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Currency
US$
Property loss (onsite)
100
Post-event summary

0.7 kg hydrogen were released.

Emergency action

The driver stopped the vehicle in a safe location, discovered that the vent valve had opened slightly, closed it and stopped the leak . The trailer could deliver at destination without further venting

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Released amount (kg)
0.7
Probable IGNITION SOURCE

References

Sources categories
PHMSA
Reference & weblink

Incident I-1996110733 of the US Pipeline and Hazardous Materials Safety Administration PHMSA:
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages&PortalPath=%…
(accessed September 2024)