Skip to main content
Clean Hydrogen Partnership

Emergency stop of CHP plant

Event

Event ID
461
Quality
Description

The incident occurred in a biogas-fed Solid Oxide Fuel Cell Stationary system, working in CHP mode.
A sudden stop of the biogas feeding line caused the safety shutdown of the plant (SOFC module).
The reason was ice formation inside the chiller (located after the biogas compressor) and inside the condensing discharge piping. This ice was creating a pressure drop across the compressor, which went into alarm mode.
By the following maintenance, more heating power has been installed on the pipelines and the ventilation speed was reduced during winter time.

Event Initiating system
Classification of the physical effects
No Hydrogen Release
Nature of the consequences
Macro-region
Europe
Country
Italy
Date
Component involved
heat exchanger (cold box)
Failure mode
internal (flow) blockage
Initiating cause
ice formation
Root CAUSE analysis

The ROOT CAUSE could be identified in a shortcoming of the design of the chiller.

Root causes
Date entry in HIAD
01/01/2019

Facility

Application
Stationary fuel cell
Sub-application
Combined Heat and Power generation
Hydrogen supply chain stage
All components affected

chiller, piping

Location type
Open
Location
industrial area
Operational condition
Pre-event occurrences

The event was unplanned. No signals or problems related to the biogas line were detected in the previous days

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Post-event summary

No consequences to people. No consequences to environment (no fuel release). The only damage is to the fuel cell plant since emergency shutdown can damage the cells.

Zero maintenance costs, the compressor was under warranty period.
Time Lost (hours): 1 month (because of Christmas break between the failure and the maintenance

Lesson Learnt

Corrective Measures

taken by the plant operator after the event:
(1) maintenance; installation of trace heating on all piping and inverter control on the ventilation blower.
(2) Monitoring of the container internal temperature during the next seasons and in particularly during the winter.
A risk assessment identified a major risk for the SOFC plant operation in the fact that there are no redundancies on the fuel feeding line.

In-depth data

Release type
no release
Released amount (kg)
0
Probable IGNITION SOURCE

References

Sources categories
Investigation report
Reference & weblink

Provided to JRC by the operator of the facility (confidential)