Skip to main content
Clean Hydrogen Partnership

Small release from a LH2 tanker

Event

Event ID
456
Quality
Description

While travelling on a highway, the driver of a liquid hydrogen tanker noticed vapour coming from under the tank control cabinet. The driver stopped at rest stop and notified the home terminal, which dispatched mechanics to the scene. They found that the pipe of the relief valve was cracked. The tank was switched to alternate pressure safety system and transported for approximately 30 miles to the home terminal without further incident. The piping was repaired and all other trailers belonging to the same series were inspected for similar problem.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
North America
Country
United States
Date
Component involved
joint/connection (valve)
Failure mode
rupture, no ignition
Initiating cause
loss of tightness (road vibrations)
Root CAUSE analysis

The INITIAL CAUSE was the failure of the pipe connecting the tank to the pressure relief valve.
Since the failure was attributed to road vibration, the ROOT CAUSE is related to shortcoming in design.

Root causes
Date entry in HIAD
01/01/2019

Facility

Application
Hydrogen transport and distribution
Sub-application
LH2 tanker
Hydrogen supply chain stage
All components affected

pipe, PRV

Process temperature range [C]
cryogenic temperature (below -50°C)
Process pressure range [MPa]
low to medium pressure (below 2 MPa)
Location type
Open
Location
highway or similar
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Currency
US$
Property loss (onsite)
960
Post-event summary

0.7 kg hydrogen were released.

Emergency action

The tank was switched to alternate pressure safety system and transported for approximately 30 miles to the home terminal without further incident.
It is unclear what the PHMSA report means by 'altenate safety'. It is probably a sort cut term for the redundant second pressure safety system.

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Released amount (kg)
0.7
Probable IGNITION SOURCE

References

Sources categories
PHMSA
Reference & weblink

Incident I-1995080699 of the US Pipeline and Hazardous Materials Safety Administration PHMSA:
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages&PortalPath=%…