Collison with vehicle

Event

Event ID
452
Quality
Description

Truck moving backwards hit a hydrogen and fuel cells bus and damaged its side mirror.

Event Initiating system
Classification of the physical effects
No Hydrogen Release
Nature of the consequences
Macro-region
Europe
Country
European Union
Date
Component involved
FCEV
Failure mode
damage, no release
Initiating cause
impact, rollover, crash
Root CAUSE analysis

INITIATING cause was a traffic accident. In absence of information on drivers and driver behaviours, the ROOT CAUSE can be attributed generically to a human error (wrong manoeuvre)

Root causes
Date entry in HIAD
01/01/2017

Facility

Application
Road vehicles
Sub-application
FCEV-bus
Hydrogen supply chain stage
All components affected

Bus body

Process temperature range [C]
ambient temperature (-50°C to +50°C)
Process pressure range [MPa]
medium to high pressure (10 to 50 MPa)
Location type
Open
Location
populated area
Operational condition
Pre-event occurrences

Hydrogen quantity indicated corresponds to the maximal average capacity of the FC buses. Real state of charge of the bus at the moment of the incidents is unknown.

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0

In-depth data

Release type
no release
Released amount (kg)
0
Release temperature [°C]
25
Release pressure [MPa]
35
Probable IGNITION SOURCE

References

Sources categories
Investigation report
Reference & weblink

Provided to JRC by the operator of the facility (confidential)