Event
- Event ID
- 374
- Quality
- Description
A liquid hydrogen tanker was loaded at the home base and dispatched to a customer (approximately 790 km). The internal vessel pressure after filling was 8 psig (1.4 bara). During transit, the pressure remained stable at 8 psig until a safety check after 8 hours indicated a pressure of 17 psig (2.2 bara).
The drivers received instructions from their home terminal to switch to the 50 psi (4.5 bara) safety relief valve. The next safety check after additional 3.5 hours revealed a pressure rise to 30 psig (3.1 bara).
The drivers were instructed to move to a safe, isolated area to conduct a controlled venting. After venting down to 18 psig, the drivers continued transit to the customer site without further blow down.- Event Initiating system
- Classification of the physical effects
- Unignited Hydrogen Release
- Nature of the consequences
- leak no ignition
- Macro-region
- North America
- Country
- United States
- Date
- Component involved
- LH2 tank (road tanker)
- Failure mode
- manual venting
- Initiating cause
- over-pressurisation (boil-off)
- Root CAUSE analysis
The INITIATING CAUSE of the event was the increase of the internal pressure of the LH2 tank.
The report does not give insights on root causes. It could have been caused ((1) by over-pressurisation (overload) during filling at the base terminal, or (2) by a reduction of the thermal insulation capacity of the tank walls. It could also (3) have been integral part of the foreseen safety measures to be undertaken to counterbalance boil-off during a long travel.
Therefore, ROOT CAUSE is unknown.
- Root causes
- Unknown
- Date entry in HIAD
- 16/11/2024
Facility
- Application
- Hydrogen transport and distribution
- Sub-application
- LH2 tanker
- Hydrogen supply chain stage
- All components affected
LH2 tank overpressure
- Process temperature range [C]
- cryogenic temperature (below -50°C)
- Process pressure range [MPa]
- low to medium pressure (below 2 MPa)
- Location type
- Open
- Location
- highway or similar
- Operational condition
Emergency & Consequences
- Number of fatalities
- 0
- Number of injured persons
- 0
- Currency
- US$
- Property loss (onsite)
- 25
- Post-event summary
A negligible amount of hydrogen was released, with a loos of only 25 US dollars
- Emergency action
A manual hydrogen vent was executed to reduce (in jargon 'to stabilise") the vapour pressure inside the LH2 tank. The drivers could handle the emergency alone.
In-depth data
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Released amount (kg)
- 0
- Release pressure [MPa]
- 0.14
- Probable IGNITION SOURCE
References
- Sources categories
- PHMSA
- Reference & weblink
Report I-1993081243 of the US Pipeline and Hazardous Materials Safety Administration PHMSA:
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages&PortalPath=%…
(accessed September 2024)