Skip to main content
Clean Hydrogen Partnership

Release of LH2 due valve failure

Event

Event ID
333
Quality
Description

During the pre-launch checkout, a check valve failed in the "open" position and an accidental venting of liquid hydrogen occurred. The event caused an unscheduled check and replacement of components.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
North America
Country
United States
Date
-
Component involved
valve (non-return)
Failure mode
leak, no ignition
Initiating cause
wrong installation
Root CAUSE analysis

An error in an installation drawing occurred in which a wrong part number was called out, resulting in system contamination and valve failure.
ROOT CAUSE was an installation error enabled by a design error. It is however unclear the reason for the mentioned contamination.

Root causes
Date entry in HIAD
30/10/2025

Facility

Application
Non-road vehicles
Sub-application
Aerospace
Hydrogen supply chain stage
All components affected

check valve

Process temperature range [C]
cryogenic temperature (below -50°C)
Location type
Unknown
Location
countryside or desert
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0

In-depth data

Release type
liquid
Involved substances (% vol)
H2 100%
Probable IGNITION SOURCE

References

Sources categories
ORDIN
Reference & weblink

Mishap no 41 in
P. L. Ordin, Review of hydrogen accidents and incidents in NASA operations, 1974, NASA TM X-71565
https://ntrs.nasa.gov/citations/19740020344

Hankinson and Lowesmith, Qualitative Risk Assessment of Hydrogen Liquefaction, Storage and Transportation, FCH JU project IDEALHY, Deliverable 3.10 (2013)
confidential
(accessed October 2025)

Lowesmith et al., Safety issues of the liquefaction, storage and transportation of liquid hydrogen: An analysis of incidents and HAZIDS, Int. J. Hydrogen energy (2014) https://doi.org/10.1016/j.ijhydene.2014.08.002